摘要

Microcalcifications can be one of the earliest signs of breast cancer. Unfortunately, their appearance in mammograms can be mimicked by dust and dirt entering the imaging process and this has been shown previously to lead to false positives. The authors use a model of the imaging process and, in particular, the blurring functions inherent within it to detect the film-screen artifacts caused by dust and dirt and, thus, reduce false-positives. A crucial facet of the work is the choice of the correct image representation upon which to perform the image processing. After extensive testing, the authors' algorithm has identified no microcalcifications as being artifacts and has an artifact detection rate of approaching 96%.
机译:微钙化可能是乳腺癌的最早迹象之一。不幸的是,灰尘和污垢进入成像过程可能会模仿其在乳房X光照片中的外观,并且先前已证明这会导致误报。作者使用成像过程的模型,尤其是其中固有的模糊功能来检测由灰尘和污垢引起的胶片屏幕伪影,从而减少假阳性。这项工作的一个关键方面是选择要在其上执行图像处理的正确图像表示。经过大量测试,作者的算法没有发现任何微钙化为伪影,伪影检测率接近96%。