首页> 外文期刊>IEEE Transactions on Medical Imaging >Noncontact 3-D Speckle Contrast Diffuse Correlation Tomography of Tissue Blood Flow Distribution
【24h】

Noncontact 3-D Speckle Contrast Diffuse Correlation Tomography of Tissue Blood Flow Distribution

机译:组织血流分布的非接触式3D斑点对比弥散相关层析成像

获取原文
获取原文并翻译 | 示例
           

摘要

Recent advancements in near-infrared diffuse correlation techniques and instrumentation have opened the path for versatile deep tissue microvasculature blood flow imaging systems. Despite this progress there remains a need for a completely noncontact, noninvasive device with high translatability from small/testing (animal) to large/target (human) subjects with trivial application on both. Accordingly, we discuss our newly developed setup which meets this demand, termed noncontact speckle contrast diffuse correlation tomography (nc_scDCT). The nc_scDCT provides fast, continuous, portable, noninvasive, and inexpensive acquisition of 3-D tomographic deep (up to 10 mm) tissue blood flow distributions with straightforward design and customization. The features presented include a finite-element-method implementation for incorporating complex tissue boundaries, fully noncontact hardware for avoiding tissue compression and interactions, rapid data collection with a diffuse speckle contrast method, reflectance-based design promoting experimental translation, extensibility to related techniques, and robust adjustable source and detector patterns and density for high resolution measurement with flexible regions of interest enabling unique application-specific setups. Validation is shown in the detection and characterization of both high and low contrasts in flow relative to the background using tissue phantoms with a pump-connected tube (high) and phantom spheres (low). Furthermore, in vivo validation of extracting spatiotemporal 3-D blood flow distributions and hyperemic response during forearm cuff occlusion is demonstrated. Finally, the success of instrument feasibility in clinical use is examined through the intraoperative imaging of mastectomy skin flap.
机译:近红外扩散相关技术和仪器的最新进展为多功能深层组织微脉管血流成像系统开辟了道路。尽管取得了这一进展,仍然需要一种完全无接触,非侵入性的设备,该设备具有很高的可翻译性,可以从小型/测试(动物)到大型/目标(人类)受试者同时进行琐碎的应用。因此,我们讨论了满足这种需求的新开发的装置,称为非接触散斑对比弥散相关层析成像(nc_scDCT)。 nc_scDCT通过简单的设计和定制即可快速,连续,便携式,无创且廉价地获取3D层析成像深层(最大10 mm)组织血流分布。呈现的功能包括用于合并复杂组织边界的有限元方法实现,避免组织压缩和相互作用的完全非接触式硬件,采用散斑对比方法的快速数据收集,基于反射的设计促进了实验翻译,对相关技术的可扩展性,以及强大的可调节源和检测器模式以及密度,可实现高分辨率测量,并具有感兴趣的灵活区域,可实现独特的特定于应用的设置。使用带有泵连接管(高)和体模球(低)的组织体模,在相对于背景的高低对比度对比的检测和表征中显示了有效性。此外,在前臂袖带阻塞期间提取时空3-D血流分布和充血反应的体内验证得到证明。最后,通过乳房切除术皮瓣的术中成像检查了该仪器在临床上的可行性是否成功。

著录项

  • 来源
    《IEEE Transactions on Medical Imaging》 |2017年第10期|2068-2076|共9页
  • 作者单位

    Department of Biomedical Engineering, University of Kentucky, Lexington, KY, USA;

    Department of Biomedical Engineering, University of Kentucky, Lexington, KY, USA;

    Department of Biomedical Engineering, University of Kentucky, Lexington, KY, USA;

    Department of Biomedical Engineering, University of Kentucky, Lexington, KY, USA;

    Division of Plastic Surgery, University of Kentucky, Lexington, KY, USA;

    Division of Plastic Surgery, University of Kentucky, Lexington, KY, USA;

    Department of Biomedical Engineering, University of Kentucky, Lexington, KY, USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Phantoms; Speckle; Blood flow; Instruments; Tomography; Detectors;

    机译:幻影;散斑;血流;仪器;层析成像;检测器;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号