首页> 外文期刊>Magnetics, IEEE Transactions on >Flux Distribution Analysis in Three-Phase Si-Fe Wound Transformer Cores
【24h】

Flux Distribution Analysis in Three-Phase Si-Fe Wound Transformer Cores

机译:三相Si-Fe绕线变压器铁心的通量分布分析

获取原文
获取原文并翻译 | 示例
       

摘要

This paper shows experimental results of longitudinal flux density and its harmonics at the limb, the yoke and the corner of a three-phase, Si-Fe, five-legged wound transformer core. Results show that the flux density is nonuniform in the cores and there is high level of third harmonic component. Moreover, the lower flux values in the outer cores have been assessed and the simultaneous time variation of the flux in both outer cores has been demonstrated by measurements while the peak magnetic flux density values have been compared to FEM analysis. These findings enable a better understanding of the magnetic behavior of five-legged wound transformer cores and their consideration is expected to achieve respective improvement of the design with respect to core losses and magnetostriction noise.
机译:本文显示了三相Si-Fe五脚绕制变压器铁心的肢体,磁轭和拐角处的纵向磁通密度及其谐波的实验结果。结果表明,磁芯中的磁通密度不均匀,并且三次谐波分量较高。此外,已经通过测量测量了外芯中较低的通量值,并且通过测量证明了两个外芯中通量的同时时间变化,同时将峰值磁通密度值与FEM分析进行了比较。这些发现使人们能够更好地理解五足绕制变压器铁芯的磁性能,并且考虑到它们的考虑,有望在铁芯损耗和磁致伸缩噪声方面实现各自的设计改进。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号