A superconducting fault current limiting transformer has been investigated to find out its feasibility. In general, the following two types of superconducting fault-current limiters could be expected: noninductive two-port and four-port devices based on superconductive-to-normal state transition. The authors have investigated the transient phenomena in the transformer and then designed a 10 kVA superconducting fault current limiting transformer. First of all, in order to understand performances during quenching in the main coils of the transformer at power system faults, no-load and short-circuit tests in the auxiliary coils were performed. With the same test for the main coils and four windings, exciting conductance, susceptance and leakage impedance were estimated. Under a constant resistive load, actual load tests and sudden short-circuit tests were carried out. Test results are presented.
机译:为了研究其可行性,对超导故障限流变压器进行了研究。通常,可以预期以下两种类型的超导故障电流限制器:基于超导到正常状态转换的非感性两端口和四端口设备。作者研究了变压器中的瞬态现象,然后设计了一个10 kVA超导故障限流变压器。首先,为了了解电力系统故障时变压器主线圈在淬火过程中的性能,对辅助线圈进行了空载和短路测试。通过对主线圈和四个绕组进行相同的测试,可以估算出励磁电导,电纳和泄漏阻抗。在恒定的电阻负载下,进行了实际负载测试和突然的短路测试。给出测试结果。