首页> 外文期刊>IEEE Transactions on Magnetics >Testing of ITER prototype cable-in-conduit conductors in the FENIX facility
【24h】

Testing of ITER prototype cable-in-conduit conductors in the FENIX facility

机译:在FENIX设施中测试ITER原型导管中电缆导体

获取原文
获取原文并翻译 | 示例
           

摘要

The Fusion Engineering International experiment (FENIX) Test Facility has been operational since 1991 at the Lawrence Livermore National Laboratory for testing the International Thermonuclear Experimental Reactor (ITER) prototype conductors. These conductors, Nb/sub 3/Sn, are designed to operate stably with transport current of more than 40 kA at magnetic field of 13 T. The FENIX facility consists of four magnet sets that are configured to allow access to the 40-cm high-field region with a test cross-section area of 10*15 cm/sup 2/. FENIX provides test conditions that closely simulate many of the ITER magnet operation modes. Performed experiments include measurements of critical current, current-sharing temperature, forced-flow properties, stability, joint performance and cyclic fatigue effects. This paper describes the design and performance of these experiments.
机译:融合工程国际实验(FENIX)测试设施自1991年在劳伦斯利弗莫尔国家实验室投入运行,用于测试国际热核实验堆(ITER)原型导体。这些导体Nb / sub 3 / Sn设计为在13 T的磁场下以大于40 kA的传输电流稳定运行。FENIX设备由四个磁体组组成,这些磁体组允许访问40 cm高测试横截面面积为10 * 15 cm / sup 2 /的磁场区域。 FENIX提供的测试条件可以紧密模拟许多ITER磁体运行模式。进行的实验包括测量临界电流,均流温度,强制流动特性,稳定性,接头性能和循环疲劳效应。本文介绍了这些实验的设计和性能。