Test of a forced-flow cooled 30 kA/23 kV current lead for the POLO model coil

机译:POLO模型线圈的强制流动冷却的30 kA / 23 kV电流引线的测试

获取原文
获取原文并翻译 | 示例
           

摘要

A 30 kA/23 kV current lead cooled by forced-flow supercritical helium has been developed at KfK. It allows position independent installation and well controlled operation which would be advantageous for operation of all kind of superconducting forced-flow cooled magnets. The design of the lead is described in this paper. The main feature is the insertion of Nb/sub 3/Sn wires inside the conductor of the heat exchanger allowing the operation at minimum mass flow in a wide current range. Measurement results are presented for steady-state operation up to 30 kA, for short time operation up to 50 kA, for pulsed operation up to /spl plusmn/1000 A at 10 Hz, and for simulation of loss of mass flow. A high-voltage test up to 28 kV DC has been done. The mass flow rate normalized to current is about 0.055 g/(s-kA) for 15 to 30 kA proving the effectiveness of the Nb/sub 3/Sn inserts. Comparison to numerical calculations shows good agreement allowing extrapolation for the design of leads for currents up to 80 kA for ITER model coil tests in the TOSKA test facility at KfK.
机译:KfK已开发出一种由强制流动超临界氦冷却的30 kA / 23 kV电流引线。它允许独立于位置的安装和良好控制的操作,这对于所有类型的超导强制流冷却磁体的操作都是有利的。本文介绍了引线的设计。主要特征是将Nb / sub 3 / Sn线插入热交换器的导体内,从而允许在较宽的电流范围内以最小质量流量运行。给出了针对高达30 kA的稳态操作,高达50 kA的短时间操作,高达10 Hz的/ spl plusmn / 1000 A的脉冲操作以及模拟质量流量损失的测量结果。已经完成了高达28 kV DC的高压测试。对于15至30 kA,归一化为电流的质量流量约为0.055 g /(s-kA),证明了Nb / sub 3 / Sn插件的有效性。与数值计算的比较表明,对于在KfK的TOSKA测试设施中进行ITER模型线圈测试的电流高达80 kA的引线设计,可以很好地推算。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号