首页> 外文期刊>IEEE Transactions on Geoscience and Remote Sensing. >Fully polarimetric microwave radiometer for remote sensing
【24h】

Fully polarimetric microwave radiometer for remote sensing

机译:全极化微波辐射计,用于遥感

获取原文
获取原文并翻译 | 示例
       

摘要

The design, characteristics, and operation of the Helsinki University of Technology Fully Polarimetric Radiometer (FPoR) are described. The developed 36.5-GHz radiometer can be used for airborne remote sensing; however, ground-based and laboratory measurements are also possible. A direct cross-correlation technique with analog correlators, which measures all four Stokes parameters simultaneously, is applied. This paper is the first successful demonstration of an analog direct cross-correlation technique for polarimetric remote sensing radiometry. The radiometer was subjected to a variety of laboratory tests, and considerable attention is given to analysis of the characteristics of the instrument. Owing to the effective active temperature control system of the receiver, the radiometric stability of the instrument was found to be very high; test results showing stabilities below 10 mK and of 4-40 mK on time scales of 800 and 8000 s, respectively, are presented. Furthermore, the absolute accuracy of the system is analyzed to be at a sub-Kelvin level for most measurement conditions. A maritime wind vector experiment was carried out over the Gulf of Finland. The feasibility and performance of the applied correlation technique and the whole radiometer system were verified for fully polarimetric airborne measurements. The obtained brightness temperatures of the first three Stokes parameters show typical harmonic behavior with respect to the surface wind; the results suggest, however, that the model coefficients presented earlier for oceans may not be directly applicable for different conditions.
机译:描述了赫尔辛基工业大学全极化辐射计(FPoR)的设计,特性和操作。研发的36.5 GHz辐射计可用于机载遥感;但是,也可以进行地面和实验室测量。采用了具有模拟相关器的直接互相关技术,该技术可以同时测量所有四个Stokes参数。本文是偏振偏振遥感辐射学中模拟直接互相关技术的首次成功演示。辐射计已经过各种实验室测试,并且相当重视分析仪器的特性。由于接收器具有有效的主动温度控制系统,因此该仪器的辐射稳定性很高。测试结果表明,分别在800和8000 s的时间范围内,稳定性低于10 mK,稳定性为4-40 mK。此外,对于大多数测量条件,系统的绝对精度被分析为处于开尔文水平。在芬兰湾进行了海上风向标实验。验证了应用相关技术和整个辐射计系统进行全极化机载测量的可行性和性能。获得的前三个Stokes参数的亮度温度显示出相对于表面风的典型谐波行为;然而,结果表明,较早提出的关于海洋的模型系数可能无法直接适用于不同条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号