摘要

This paper presents the application of a new hydroelectric generator air-gap measurement system. It is a continuous on-line system using optical triangulation, fiber-optics, a microprocessor-based monitor, specially developed instrumentation and power supplies. This system is noninvasive, insensitive to EMI, and has 0.2 percent accuracy over a range of 2 to 40 mm. The paper presents air-gap data obtained from B.C. Hydro's Mica Creek Unit G2 (457 MVA) during March 1986. Readings were taken from stator-to-rotor and from rotor-to-stator to determine the unit's characteristics prior to rotor rim shrink modifications. These data assisted in determining the individual contributions of the rotor and the stator to the generator's behavior and provides a comparison for post-modification testing.
机译:本文介绍了一种新型水力发电机气隙测量系统的应用。它是使用光学三角测量,光纤,基于微处理器的监视器,专门开发的仪器和电源的连续在线系统。该系统是非侵入性的,对EMI不敏感,在2至40 mm范围内的精度为0.2%。本文介绍了从卑诗省获得的气隙数据。 Hydro的Mica Creek机组G2(457 MVA)在1986年3月。从定子到转子和转子到定子的读数来确定机组的特性,然后再修改转子轮缘的收缩率。这些数据有助于确定转子和定子对发电机性能的单独影响,并为修改后的测试提供了比较。