首页> 外文期刊>IEEE Microwave and Guided Wave Letters >A simple error correction method for two-port transmission parameter measurement
【24h】

A simple error correction method for two-port transmission parameter measurement

机译:两端口传输参数测量的一种简单的纠错方法

获取原文
获取原文并翻译 | 示例

摘要

This letter presents a simple error correction method for two-port transmission parameter measurement. The method requires measuring only two nonreflecting transmission lines instead of a complete set of calibration standards (at least three) for error correction, it does not need an explicit solution of error coefficients. These two features make it simpler than any other methods. Error-corrected measurement results of a CPW discontinuity using the new method and the TRL method are in good agreement. The new method is useful in characterizing well-matched two-port devices or those whose reflection parameters are of little interest.
机译:这封信提出了一种简单的用于两端口传输参数测量的纠错方法。该方法仅需要测量两条非反射传输线,而不是用于误差校正的完整的校准标准集(至少三套),它不需要明确的误差系数解决方案。这两个功能使它比其他任何方法都更简单。使用新方法和TRL方法对CPW不连续性进行误差校正的测量结果非常吻合。新方法可用于表征匹配良好的两端口器件或反射参数不重要的器件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com