首页> 外文期刊>Heat Transfer Engineering >Heat Transfer Analysis for a Concentric Tube Heat Exchanger Including the Wall Axial Conduction
【24h】

Heat Transfer Analysis for a Concentric Tube Heat Exchanger Including the Wall Axial Conduction

机译:包括壁面轴向传导的同心管式换热器的传热分析

获取原文
获取原文并翻译 | 示例
       

摘要

The effect of wall axial conduction on the heat transfer in a concentric tube heat exchanger is examined for the inner flow laminar flow regime. The procedure used for the current analysis combines the analytical solution for the inner fluid with a numerical approximation for the wall conduction and has the capability of handling the temperature variation for the outer fluid. Both parallel and counterflow cases are evaluated for the analysis, and results are presented in terms of the axial variations of fluids and wall temperatures. Effects of the heat capacity rate ratio of the fluids on the temperature variations and on the mean heat flux are also pointed out. The effect of the exchanger length is included for the analysis. It is concluded that the total heat transfer between the fluids is greatly influenced by the wall axial conduction for the counterflow arrangement and is not ignorable when the heat capacity rate ratio of fluids are smaller than unity.
机译:对于内流层流状态,研究了壁轴向传导对同心管式换热器中传热的影响。用于当前分析的过程将内部流体的分析解决方案与壁传导的数值近似值结合在一起,并具有处理外部流体的温度变化的能力。评估了平行和逆流情况,以进行分析,并以流体的轴向变化和壁温表示结果。还指出了流体的热容量比率对温度变化和平均热通量的影响。交换器长度的影响包括在分析中。结论是,流体之间的总热传递在很大程度上受逆流装置的壁轴向传导的影响,并且当流体的热容比小于1时是不可忽略的。