The district heating system is currently operating at one third to one half of design thermal capacity. However, the distribution system is near hydraulic capacity due to uncontrolled flow at several buildings. With improved flow control resulting in increased system ΔT, the system can support significant additional expansion. The district heating system is currently functioning adequately and reliably on mostly manual control. Control improvements would improve operation and reliability and reduce operating cost. The system is basically mechanically sound. Maintenance is needed, especially in the area of corrosion control to keep the system sound. Although the district heating system is not yet financially self-supporting, this study recommends additional investment in the system. The payback from that investment will come in the form of operational cost savings, continued reliability and community support, and ability to increase revenue with further system expansion.
机译:目前,区域供热系统的运行功率为设计热容量的三分之一至一半。但是,由于多个建筑物的流量不受控制,因此分配系统接近水力容量。通过改善流量控制,可增加系统的ΔT,该系统可支持显着的额外扩展。目前,区域供热系统在大多数手动控制下均能正常运行。控制方面的改进将改善操作和可靠性并降低操作成本。该系统基本上是机械健全的。需要维护,尤其是在腐蚀控制领域,以保持系统正常运行。尽管区域供热系统在财务上还不能自给自足,但本研究建议对该系统进行额外的投资。这项投资的回报将以节省运营成本,持续的可靠性和社区支持以及通过进一步扩展系统来增加收入的能力的形式出现。