首页> 外文期刊>Generation, Transmission & Distribution, IET >Analytical technique for synchronous generator loss-of-excitation protection
【24h】

Analytical technique for synchronous generator loss-of-excitation protection

机译:同步发电机失磁保护的分析技术

获取原文
获取原文并翻译 | 示例
           

摘要

This study introduces a new analytical approach for the detection of loss of excitation (LOE) in a synchronous generator that uses only one local variable. The proposed method applies the mathematical analysis based on the generator armature current variation. In this method, after the generator loses its excitation, the second order derivative of generator armature current becomes and remains positive until a loss of synchronism event occurs. Simulations are performed for different levels of generator conditions and loads, and the results confirm the mathematical analysis. To demonstrate the suitability of the proposed method, comparisons are made with other protection methods. Studies show that the proposed strategy offers a better security and faster detection of LOE compared with the previous methods.
机译:这项研究介绍了一种新的分析方法,用于检测仅使用一个局部变量的同步发电机中的励磁损耗(LOE)。所提出的方法基于发电机电枢电流变化进行数学分析。在这种方法中,发电机失去励磁后,发电机电枢电流的二阶导数变为并保持正值,直到发生同步事件丢失。针对不同级别的发电机条件和负载进行了仿真,结果证实了数学分析。为了证明该方法的适用性,将其与其他保护方法进行了比较。研究表明,与以前的方法相比,提出的策略可提供更好的安全性和更快的LOE检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号