In normal experimental operation, a diagnostic neutral beam (DNB) can produce 6 A of extracted beam current in hydrogen at an energy of 49 keV with a pulse length of 100 ms. Hydrogen and deuterium beams can be produced as well. The diagnostic neutral beam has been added to the diagnostic set so that charge-exchange recombination spectroscopy (CXRS) can be used to acquire ion temperature and rotation. The beam power and beam profile distribution of the DNB injection can be obtained with a thermocouple probe measurement system on the HT-7 superconducting tokamak. The thermocouple probe measurement system with 13 thermocouples crossly distributed on the probe plate was used to measure the temperature rise of each coppery target, so the profile distribution of the ioneutral beam was obtained by calculation. In this paper, the structure of the probe plate on the DNB for HT-7 tokamak and some measurement results are presented.
机译:在正常的实验操作中,诊断性中性束(DNB)可以在49 keV的能量下以100 ms的脉冲长度在氢气中产生6 A的提取束电流。也可以产生氢束和氘束。诊断中性束已添加到诊断设备中,以便可以使用电荷交换重组光谱(CXRS)来获取离子温度和旋转。可以使用HT-7超导托卡马克上的热电偶探针测量系统获得DNB注入的射束功率和射束轮廓分布。使用在探针板上交叉分布有13个热电偶的热电偶探针测量系统来测量每个铜质靶的温度升高,因此可以通过计算获得离子/中性束的分布。本文介绍了HT-7托卡马克DNB探针板的结构和一些测量结果。