首页> 外文期刊>Fusion Engineering and Design >Experimental and numerical evaluation of IR thermography method for Final Acceptance Tests of the ITER divertor dome
【24h】

Experimental and numerical evaluation of IR thermography method for Final Acceptance Tests of the ITER divertor dome

机译:红外热成像方法对ITER偏滤器圆顶最终验收测试的实验和数值评估

获取原文
获取原文并翻译 | 示例
           

摘要

The divertor dome (DO), being part of the ITER divertor, is designed to extract the major part of the plasma thermal energy. As a plasma-facing component (PFC), the DO experiences high heat fluxes (up to 5.0MW/m~2). Such severe operation conditions of the DO imply stringent requirements for the DO design and its cooling system to ensure the required temperature operation regime of the dome. Hence, Final Acceptance Tests (FAT) shall be performed on each DO final assembled component with the aim to demonstrate that none of parallel coolant channels are completely or partially blocked. The paper presents the results of the analytical and experimental testing of the thermography method capability to perform the FAT. The aim is to determine defective hypervapotrons of the divertor dome. The method consists in contactless measurement of the dynamic temperature field of the PFC surface at a step-like increase (from zero to constant value) in the coolant flow rate with a temperature higher than that of the hypervapotron.
机译:作为ITER偏滤器的一部分的偏滤器圆顶(DO)旨在提取等离子体热能的主要部分。作为等离子体等离子组件(PFC),DO的热通量高(高达5.0MW / m〜2)。 DO的这种苛刻的运行条件意味着对DO设计及其冷却系统的严格要求,以确保所需的球顶温度运行状况。因此,应在每个DO最终组装部件上执行最终验收测试(FAT),以证明平行冷却剂通道没有被完全或部分堵塞。本文介绍了热成像方法执行FAT的能力的分析和实验测试的结果。目的是确定偏斜器圆顶的缺陷性超高压。该方法包括在冷却剂流量呈阶梯状增加(从零到恒定值)且温度高于超高压釜的情况下,非接触式测量PFC表面的动态温度场。

著录项

  • 来源
    《Fusion Engineering and Design》 |2014年第8期|925-931|共7页
  • 作者单位

    Scientific Technical Center SINTEZ, D.V. Efremov Institute, 196641 St. Petersburg, Russia;

    Scientific Technical Center SINTEZ, D.V. Efremov Institute, 196641 St. Petersburg, Russia;

    Scientific Technical Center SINTEZ, D.V. Efremov Institute, 196641 St. Petersburg, Russia;

    Scientific Technical Center SINTEZ, D.V. Efremov Institute, 196641 St. Petersburg, Russia;

    Scientific Technical Center SINTEZ, D.V. Efremov Institute, 196641 St. Petersburg, Russia;

    I.I. Polzunov Scientific & Development Association on Research and Design of Power Equipment, 191167 St. Petersburg, Russia;

    I.I. Polzunov Scientific & Development Association on Research and Design of Power Equipment, 191167 St. Petersburg, Russia;

    I.I. Polzunov Scientific & Development Association on Research and Design of Power Equipment, 191167 St. Petersburg, Russia;

    I.I. Polzunov Scientific & Development Association on Research and Design of Power Equipment, 191167 St. Petersburg, Russia;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    ITER divertor dome; Defective hypervapotrons; Final Acceptance Tests; Thermography method; Contactless measurement; Dynamic temperature field;

    机译:ITER偏滤器圆顶;超vapotrons缺陷;最终验收测试;热成像方法;非接触式测量;动态温度场;