首页> 外文期刊>Fusion Engineering and Design >The analytical gas chromatographic system of the JET Active Gas Handling System-tritium commissioning and use durina DTE1
【24h】

The analytical gas chromatographic system of the JET Active Gas Handling System-tritium commissioning and use durina DTE1

机译:JET活性气体处理系统的分析型气相色谱系统-t调试和使用durina DTE1

获取原文
获取原文并翻译 | 示例
       

摘要

The analytical gas chromatographic system (AN-GC) was the main tool used to analyse gas mixtures from various subsystems of the Active Gas Handling System (AGHS) and to characterise the functioning of the different processes during the Deuterium-Tritium Experiment (DTE1). Samples were transferred to AN-GC via long (1/4)" lines. Calibration factors, accuracy and minimum detection limits for different gas species were determined for the thermal conductivity detectors, flame ionisation detectors and ionisation chambers. The performance of the AN-GC is discussed by means of various chromatograms and the experience gained with these detectors as well as their limits are mentioned. The AN-GC worked very reliably and about 320 analyses were performed during DTEI and the subsequent cleanup phase.
机译:分析型气相色谱系统(AN-GC)是用于分析来自活性气体处理系统(AGHS)各个子系统的气体混合物以及表征氘T实验(DTE1)中不同过程功能的主要工具。样品通过长(1/4)“线传输到AN-GC。确定了热导检测器,火焰电离检测器和电离室的不同气体种类的校准系数,准确度和最低检测限。AN-通过各种色谱图对GC进行了讨论,并提到了这些检测器获得的经验及其极限值,AN-GC工作非常可靠,在DTEI和随后的净化阶段进行了约320次分析。