...
首页> 外文期刊>Biomedizinische Technik >Non-invasive determination of instantaneous brachial blood flow using the oscillometric method
【24h】

Non-invasive determination of instantaneous brachial blood flow using the oscillometric method

机译:示波法无创测定瞬时臂式血流

获取原文
获取原文并翻译 | 示例
           

摘要

The oscillometric method has been widely used to measure arterial systolic and diastolic blood pressures, but its potential for arterial blood flow measurements still remains to be explored. The aim of this study was to non-invasively determine arterial blood flow using an oscillometric blood flow measurement system. The system consists of a pneumatic elastic cuff, an air-pumping motor, a releaser valve, a pressure transducer, and an airflow meter. To build a non-linear cuff model, we measured airflow pumped into the pneumatic cuff and cuff pressure using an airflow meter and pressure transducer during the inflation period, respectively. During the deflation period, only the pressure transducer was used to record cuff pressure. Based on the cuff model, the oscillometric blood flow waveform was obtained by integrating the oscillometric pressure waveform. We compared arterial blood flow derived from the maximum amplitude of the oscillometric blood flow waveform with Doppler-measured blood flow calculated with the diameters and blood velocities of the brachial arteries in 32 subjects who underwent diagnostic evaluations for peripheral arterial embolism. A linear correlation coefficient of r= 0.716 was found between the oscillometry- and Doppler-based blood flow measurements in the 32 subjects. These results suggest that blood flow passing through the brachial artery can be quantified non-invasively using the oscillometric approach after appropriate calibration.
机译:示波法已被广泛用于测量动脉收缩压和舒张压,但其在动脉血流测量中的潜力仍有待探索。这项研究的目的是使用示波法血流测量系统以非侵入性方式确定动脉血流。该系统包括一个气动弹性袖带,一个抽气马达,一个释放阀,一个压力传感器和一个空气流量计。为了建立非线性袖带模型,我们分别在充气期间使用气流计和压力传感器测量了泵入气动袖带的气流和袖带压力。在放气期间,仅使用压力传感器记录袖带压力。在袖带模型的基础上,通过积分示波压力波形获得示波血流波形。我们比较了示波法血流波形的最大幅度得出的动脉血流与多普勒测得的血流,该多普勒测得的血流是根据32位接受了外周动脉栓塞诊断评估的受试者的肱动脉的直径和血流速度计算得出的。在32位受试者的基于示波法和多普勒的血流测量之间发现线性相关系数r = 0.716。这些结果表明,经过适当的校准后,可以使用示波法对通过肱动脉的血流进行无创定量。

著录项

  • 来源
    《Biomedizinische Technik》 |2009年第4期|171-177|共7页
  • 作者单位

    Department of Computer Science and Information Engineering, Chaoyang University of Technology, Taichung, Taiwan, Republic of China;

    Department of Biomedical Engineering, I-Shou University, Kaoshiung, Taiwan, Republic of China Department of Biomedical Engineering, I-Shou University 1, Section 1, Hsueh-Cheng Road, Ta-Hsu Hsiang, Kaohsiung County, Taiwan 84008, Republic of China;

    Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan, Republic of China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    arterial blood flow; cuff model; doppler; oscillometric pressure waveform; oscillometry;

    机译:动脉血流袖口模型多普勒示波压力波形;示波法;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号