首页> 外文期刊>Biomedizinische Technik >Immediate loading of an implant with fine threaded neck - bone resorption and clinical outcome of single tooth restorations in the maxilla
【24h】

Immediate loading of an implant with fine threaded neck - bone resorption and clinical outcome of single tooth restorations in the maxilla

机译:立即装载具有细牙颈部的植入物-骨吸收和上颌中单颗牙齿修复的临床结果

获取原文
获取原文并翻译 | 示例
           

摘要

One of the conditions for ensuring success in implant surgery with an immediate loading (IL) protocol is to achieve maximum primary stability (PS) through the use of dental implants with the appropriate design and surface and a properly prepared osseous bed. The aim of this study was to assess the stability, degree of osseointegration, and success rate after inserting an implant with IL in an osseous bed prepared with burs or an ultrasonic device. Twenty-five patients requiring single tooth replacement (tioLogic; Dentaurum, Ispringen, Germany) in the aesthetic zone were divided randomly into the test (K0) and control (K1) groups. The following factors were investigated: primary (PS-ISQ) and secondary (SS-ISQ) stability- implant stability quotient (ISQ value) by Ostell Mentor, initial width of the alveolar ridge, marginal bone loss (MBL), and buccal bone thickness. The effectiveness of the implant treatment 1 year after the surgery was 100% for group KO and 93.3% for group Kl. A significant correlation was observed between PS and MBL after 1 month. No statistically significant differences were noted between the groups with regard to MBL after 6 months (K0 0.5±0.4 mm vs. K1 0.8±1.3 mm), PS-ISQ (KO070±4 vs. K1 71±4), and SS-ISQ (K0 70±2 vs. K1 72±3). The average ISQ value of 70±4 is sufficient to allow for IL. A high level of PS results in lower MBL.
机译:使用即时加载(IL)方案确保植入物手术成功的条件之一是通过使用具有适当设计和表面以及适当准备的骨床的牙科植入物来获得最大的基本稳定性(PS)。这项研究的目的是评估在用Burs或超声仪准备的骨床中植入IL植入物后,评估稳定性,骨整合度和成功率。将25名需要在美容区进行单颗牙齿替换的患者(tioLogic; Dentaurum,Ispringen,德国)随机分为测试组(K0)和对照组(K1)。研究了以下因素:主要(PS-ISQ)和次要(SS-ISQ)稳定性-Ostell Mentor的植入物稳定性商(ISQ值),牙槽的初始宽度,边缘性骨丢失(MBL)和颊骨厚度。手术后一年的植入物治疗对KO组为100%,对于K1组为93.3%。 1个月后,PS和MBL之间观察到显着相关性。 6个月后MBL(K0 0.5±0.4 mm vs. K1 0.8±1.3 mm),PS-ISQ(KO070±4 vs. K1 71±4)和SS-ISQ在两组之间无统计学差异。 (K0 70±2与K1 72±3)。平均ISQ值为70±4足以允许IL。 PS含量高会导致MBL降低。

著录项

  • 来源
    《Biomedizinische Technik》 |2012年第1期|p.3-9|共7页
  • 作者单位

    Department of Dental Surgery, Wroclaw Silesian Piast Medical University, Wroclaw, Poland;

    Department of Orthodontics, Pediatric Dentistry and Preventative Dentistry, Ernst-Moritz-Arndt Medical University, Greifswald, Germany;

    Department of Dental Surgery, Wroclaw Silesian Piast Medical University, Wroclaw, Poland,Department of Orthodontics, Pediatric Dentistry and Preventative Dentistry, Ernst-Moritz-Arndt Medical University, Greifswald, Germany;

    Department of Orthodontics, Wroclaw Silesian Piast Medical University, Wroclaw, Poland;

    Department of Maxillo-Facial Surgery, Wroclaw Silesian Piast Medical University, Wroclaw, Poland;

    Department of Oral Surgery, Silesian Piast Medical University, Krakowska 26, 50-424 Wroclaw, Poland;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    immediate loading; implants; ultrasonic preparation;

    机译:立即加载;植入物超声波制备;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号