A radiological method to determine the accuracy of motion capture marker placement on palpable anatomical landmarks through a shoe

机译:一种通过鞋子确定运动捕获标记在可触及的解剖界标上放置的准确性的放射学方法

获取原文
获取原文并翻译 | 示例

摘要

The accuracy of marker placement on palpable surface anatomical landmarks is an important consideration in biomechanics. Although marker placement reliability has been studied in some depth, it remains unclear whether or not the markers are accurately positioned over the intended landmark in order to define the static position and orientation of the segment. A novel method using commonly available X-ray imaging was developed to identify the accuracy of markers placed on the shoe surface by palpating landmarks through the shoe. An anterior-posterior and lateral-medial X-ray was taken on 24 participants with a newly developed marker set applied to both the skin and shoe. The vector magnitude of both skin- and shoe-mounted markers from the anatomical landmark was calculated, as well as the mean marker offset between skin- and shoe-mounted markers. The accuracy of placing markers on the shoe relative to the skin-mounted markers, accounting for shoe thickness, was less than 5 mm for all markers studied. Further, when using the developed guidelines provided in this study, the method was deemed reliable (Intra-rater ICCs = 0.50-0.92). In conclusion, the method proposed here can reliably assess marker placement accuracy on the shoe surface relative to chosen anatomical landmarks beneath the skin.
机译:在可触知的表面解剖界标上放置标记的准确性是生物力学中的重要考虑因素。尽管已经对标记放置的可靠性进行了一定深度的研究,但仍不清楚是否将标记精确地定位在目标地标上以定义段的静态位置和方向。开发了一种使用常用的X射线成像的新颖方法,以通过在鞋上触碰界标来识别放置在鞋表面上的标记的准确性。用新开发的适用于皮肤和鞋子的标记物组对24位参与者进行了前后,内侧和外侧X射线检查。计算了来自解剖界标的皮肤和鞋上标记的矢量幅度,以及皮肤和鞋上标记之间的平均标记偏移。相对于皮肤安装的标记,在鞋子上放置标记的准确性(考虑到鞋子的厚度)对于所有研究的标记而言均小于5 mm。此外,当使用本研究中提供的开发的指南时,该方法被认为是可靠的(评估者内部ICC = 0.50-0.92)。总之,这里提出的方法可以相对于皮肤下选定的解剖学界标可靠地评估鞋表面上的标记放置精度。

著录项

  • 来源
    《Footwear science》 |2011年第3期|p.169-177|共9页
  • 作者单位

    School of Health Science, University of South Australia, Adelaide, Australia;

    School of Health Science, University of South Australia, Adelaide, Australia Sansom Institute for Health Research,University of South Australia, Adelaide, Australia;

    School of Health Science, University of South Australia, Adelaide, Australia;

    School of Health Science, University of South Australia, Adelaide, Australia;

    Ergo Lab, Mawson Institute, University of South Australia,Adelaide, Australia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    anatomical markers; kinematic model; x-ray; reliability; foot and ankle;

    机译:解剖标记运动学模型X射线可靠性;脚和脚踝;