A simple and robust method for the determination of 18 polychlorinated biphenyls (PCBs) in fish was developed and validated. A mixture of acetone-hexane (1:1, v/v) was selected for accelerated solvent extraction (ASE). After the digestion of fat, the clean-up was carried out using solid phase extraction silica cartridges. Samples were analysed by GC-MS in selected ion monitoring (SIM) using three fragment ions for each congener (one quantifier and two qualifiers). PCB 155 and PCB 198 were employed as internal standards. The lowest limit of detection was observed for PCB 28 (0.4 ng/g lipid weight). The accuracy of the method was verified by means of the Certified Reference Material EDF-2525 and good results in terms of linearity (R~2 > 0.994) and recoveries (80-110%) were also achieved. Precision was evaluated by spiking blank samples at 4,8 and 12 ng/g. Relative standard deviation values for repeatability and reproducibility were lower than 8% and 16%, respectively. The method was applied to the determination of PCBs in 80 samples belonging to four Mediterranean fish species. The proposed procedure is particularly effective because it provides good recoveries with lowered extraction time and solvent consumption; in fact, the total time of extraction is about 12 min per sample and, for the clean-up step, a total solvent volume of 13 ml is required.
机译:开发并验证了一种简单稳定的测定鱼中18种多氯联苯(PCBs)的方法。选择丙酮/正己烷的混合物(1:1,v / v)进行加速溶剂萃取(ASE)。消化脂肪后,使用固相萃取硅胶滤芯进行清洁。样品通过选择离子监测(SIM)中的GC-MS分析,每个同类物使用三个碎片离子(一个定量器和两个定量器)。 PCB 155和PCB 198被用作内部标准。观察到最低的PCB 28检测限(0.4 ng / g脂质重量)。该方法的准确性已通过认证的参考材料EDF-2525进行了验证,并且在线性度(R〜2> 0.994)和回收率(80-110%)方面均取得了良好的结果。通过以4,8和12 ng / g加标空白样品来评估精密度。重复性和再现性的相对标准偏差值分别低于8%和16%。该方法用于测定四种地中海鱼类的80个样品中的多氯联苯。所提出的方法特别有效,因为它提供了良好的回收率,同时减少了萃取时间和溶剂消耗。实际上,每个样品的总提取时间约为12分钟,并且对于净化步骤而言,需要的总溶剂体积为13 ml。

著录项

  • 来源
    《Food Chemistry》 |2014年第1期|327-333|共7页
  • 作者单位

    Dipartimento di Chimica e Chimica Industriale, Universita degli Studi di Genova, Via Dodecaneso 31, 16146 Genova, Italy Istituto Italiano di Tecnologia, Unit of Drug Discovery and Development, Via Morego 30,16163 Genova, Italy;

    Istituto Zooprofilattico Sperimemale del Piemonte, Liguria e Valle d'Aosta, Sezione di Genova, Piazza Borgo Pila 39/24, 16129 Cenova, Italy;

    Dipartimento di Chimica e Chimica Industriale, Universita degli Studi di Genova, Via Dodecaneso 31, 16146 Genova, Italy;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Polychlorinated biphenyls (PCBs); Accelerated solvent extraction (ASE); Gas chromatography-mass spectrometry; (GC-MS); Fish;

    机译:多氯联苯(PCB);加速溶剂萃取(ASE);气相色谱-质谱法;(GC-MS);鱼;