The use of slurry sampling as the procedure for sample preparation provides simplicity, speed, and low consumption of reagents in analytical methods. In this paper, a method based on slurry sampling for the determination of iron in samples of fortified milk powder by high-resolution continuum source flame atomic absorption spectrometry was developed. Multivariate design techniques were applied for the optimization of experimental conditions of the method for a sample mass of 100 mg, final volume of slurry of 10 mL, and using the absorbance signal as response. Initially, a two-level full factorial design was used for the preliminary evaluation of the variables involved in slurry preparation: concentration hydrochloric acid, Triton X-100 concentration, and sonication time. Then, the Doehlert matrix was applied for the determination of the critical conditions: 2.5 mol L−1 hydrochloric acid and sonication time of 20 min. External calibration technique with aqueous standard was used for the quantification of iron. This way, the method allowed iron determination with limits of detection and quantification of 0.9 and 3.0 μg g−1, respectively. The precision expressed as the relative standard deviation was evaluated under repeatability and reproducibility conditions, being 3.2% and 4.0%, respectively. Addition/recovery test was used for assessing the accuracy of the method, and the recovery values achieved were in the range of 90–110%. The method was applied for iron determination in eight samples of fortified milk powder, and the obtained concentrations varied from 95.4 to 295.6 μg g−1. The results were compared with those obtained after acid digestion, and no significant difference was observed applying t test at the 95% confidence level.
机译:使用泥浆采样作为样品制备过程可简化分析方法,提高速度并降低试剂消耗。本文提出了一种基于浆液采样的高分辨率连续流源火焰原子吸收光谱法测定强化奶粉中铁的方法。将多变量设计技术应用于该方法的实验条件的优化,样品质量为100 mg,浆液最终体积为10 mL,并使用吸光度信号作为响应。最初,采用两级全因子设计来初步评估浆液制备中涉及的变量:盐酸浓度,Triton X-100浓度和超声处理时间。然后,将Doehlert基质用于确定临界条件:2.5 mol L -1 盐酸和超声处理时间为20分钟。使用含水标准液的外部校准技术对铁进行定量。这样,该方法可以测定铁,检测限和定量限分别为0.9和3.0μgg -1 。在重复性和重现性条件下,以相对标准偏差表示的精密度分别为3.2%和4.0%。使用添加/回收率测试评估方法的准确性,回收率达到90-110%。该方法用于八份强化奶粉样品中铁的测定,所得浓度范围为95.4至295.6μgg -1 。将结果与酸消解后获得的结果进行比较,在95%置信水平下使用t检验未观察到显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号