...
首页> 外文期刊>Food Additives & Contaminants >Assessment Of A New Lateral Flow Immunochromatographic (lfic) Assay For The Okadaic Acid Group Of Toxins Using Naturally Contaminated Bivalve Shellfish From The Portuguese Coast
【24h】

Assessment Of A New Lateral Flow Immunochromatographic (lfic) Assay For The Okadaic Acid Group Of Toxins Using Naturally Contaminated Bivalve Shellfish From The Portuguese Coast

机译:使用葡萄牙海岸天然污染的双壳贝类对冈田酸毒素的一种新的侧向流免疫色谱(lfic)分析方法进行评估

获取原文
获取原文并翻译 | 示例
           

摘要

A new rapid assay for the okadaic acid group of toxins, based on lateral flow immunochromatographic (LFIC) test strips developed by Jellett Rapid Testing Ltd., was assessed on naturally contaminated bivalves from the Portuguese coast. One prototype was evaluated using samples harvested during 2005, extracted with 80% methanol, followed by dilution with the running buffer of a methanolic extract after alkaline hydrolysis for esters. The second prototype was assessed using samples harvested during 2006, extracted with 100% methanol and, after alkaline hydrolysis, the methanol was evaporated by a nitrogen stream followed by re-suspension with the running buffer. The first prototype failed to detect 20% of samples that were positive by LC-MS in the range 160-480 μg kg~(-1), and were classified as negative or trace level by LFIC. The presence of methanol in the extracts made correct detection of toxins more difficult. The second prototype classified as positive all samples above 160 μg kg~(-1), as confirmed by LC-MS. However, in the second prototype, matrix effects were a major drawback and led to 45% false positives, particularly for mussels, due to compounds in shellfish extracts interfering with the antibodies and reducing the test line intensity. Extraction with a higher percentage of methanol was thought responsible for these matrix effects. Regarding sample migration, both prototypes needed one hour before reading. In an attempt to speed-up sample preparation, a direct digestion of bivalve tissues with sodium hydroxide was evaluated. Low recoveries for esters were found by LC-MS with this hydrolysis technique compared to conventional hydrolysis of methanolic extracts. While prototype A was not sensitive enough, prototype B had too many false positives to be of use to the shellfish industry or in a monitoring program.
机译:在Jellett Rapid Testing Ltd.开发的侧向流免疫色谱(LFIC)试纸的基础上,对葡萄牙海岸天然污染的双壳类动物进行了一项新的冈田酸毒素快速检测方法。使用2005年收获的样品评估了一个原型,样品用80%甲醇萃取,然后在碱水解酯后用甲醇萃取液的运行缓冲液稀释。使用2006年收获的样品评估第二个原型,样品用100%甲醇萃取,碱水解后,甲醇通过氮气流蒸发,然后重新悬浮于运行缓冲液中。第一个原型未能通过LC-MS检测到20%的160-480μgkg〜(-1)范围内为阳性的样品,并且被LFIC分类为阴性或痕量水平。提取物中甲醇的存在使得正确检测毒素更加困难。 LC-MS证实,第二个原型将160μgkg〜(-1)以上的所有样品分类为阳性。但是,在第二个原型中,由于贝类提取物中的化合物会干扰抗体并降低测试线强度,因此基质效应是主要缺陷,并导致45%的假阳性,尤其是贻贝。人们认为用较高百分比的甲醇萃取是造成这些基质效应的原因。关于样本迁移,两个原型需要一个小时才能阅读。为了加快样品制备速度,评估了用氢氧化钠直接消化双壳类动物组织的方法。与常规的甲醇萃取物水解相比,采用这种水解技术通过LC-MS发现酯的回收率较低。尽管原型A不够灵敏,但原型B的假阳性太多,无法用于贝类行业或监控程序。

著录项

  • 来源
    《Food Additives & Contaminants》 |2009年第2期|214-220|共7页
  • 作者单位

    Instituto National dos Recursos Biologicos-IPIMAR, Av. Brasilia, s, 1449-006 Lisbon, Portugal;

    rnInstituto National dos Recursos Biologicos-IPIMAR, Av. Brasilia, s, 1449-006 Lisbon, Portugal;

    rnInstituto National dos Recursos Biologicos-IPIMAR, Av. Brasilia, s, 1449-006 Lisbon, Portugal;

    rnInstituto National dos Recursos Biologicos-IPIMAR, Av. Brasilia, s, 1449-006 Lisbon, Portugal;

    rnInstituto National dos Recursos Biologicos-IPIMAR, Av. Brasilia, s, 1449-006 Lisbon, Portugal;

    rnJellett Rapid Testing Ltd., 4654 Route 3, Chester Basin, Nova Scotia, Canada BOJ 1K0;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    lateral flow immunochromatography; lfic; lc-ms; okadaic acid; acyl esters; hydrolysis;

    机译:侧向免疫色谱;柠檬酸;LC-MS;冈田酸;酰基酯;水解;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号