首页> 外文期刊>Food Additives & Contaminants >Quantification of caffeine in dietary supplements and energy drinks by solid-surface fluorescence using a pre-concentration step on multi-walled carbon nanotubes and Rhodamine B
【24h】

Quantification of caffeine in dietary supplements and energy drinks by solid-surface fluorescence using a pre-concentration step on multi-walled carbon nanotubes and Rhodamine B

机译:使用多壁碳纳米管和若丹明B上的预浓缩步骤通过固体表面荧光定量膳食补充剂和能量饮料中的咖啡因

获取原文
获取原文并翻译 | 示例

摘要

A new method for the determination of caffeine, a non-fluorescent analyte, based on the enhancement of the fluorescence of Rhodamine B dye on a membrane filter modified with multi-walled carbon nanotubes is proposed. The method comprises pre-concentration of caffeine on a solid support by chemofiltration in buffered solution onto multi-walled carbon nanotubes previously oxidised and dispersed in cationic surfactant admicelles. The effect of experimental parameters, including the nature of the buffer and pH, the nature of the solid support, filtration flow rate, dye and carbon nanotube concentration, and the nature of the surfactant and concentration were investigated by means univariation assays. Under optimum experimental conditions, the pre-concentration system gave detection and quantification limits of 0.3 and 1.1 μg 1~(-1), respectively. A wide linear range was achieved varying from concentrations of 1.1 to 9.7×103 μg 1~(-1) (r~2 = 0.999). Satisfactory recovery values were obtained using the method of standard addition, confirming the feasibility of this method for caffeine determination in energising dietary supplements and energy drinks.
机译:提出了一种基于多壁碳纳米管修饰的膜滤膜上若丹明B染料荧光增强的测定咖啡因的非荧光分析新方法。该方法包括通过在缓冲溶液中化学过滤将咖啡因在固体支持物上预浓缩到预先氧化并分散在阳离子表面活性剂微粒中的多壁碳纳米管上。通过单变量分析研究了实验参数的影响,包括缓冲液的性质和pH值,固体载体的性质,过滤流速,染料和碳纳米管的浓度以及表面活性剂和浓度的性质。在最佳实验条件下,预浓缩系统的检测限和定量限分别为0.3和1.1μg1〜(-1)。浓度范围从1.1到9.7×103μg1〜(-1)(r〜2 = 0.999),变化范围很大。使用标准添加方法获得了令人满意的恢复值,证实了该方法在补充膳食补充剂和能量饮料中咖啡因含量方面的可行性。

著录项

  • 来源
    《Food Additives & Contaminants 》 |2014年第8期| 1367-1374| 共8页
  • 作者单位

    Instituto de Quimica de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, 5700 San Luis, Argentina;

    Instituto de Quimica de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, 5700 San Luis, Argentina;

    Area de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad National de San Luis, San Luis, Argentina;

    Area de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad National de San Luis, San Luis, Argentina;

    Area de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad National de San Luis, San Luis, Argentina,Instituto de Quimica de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, 5700 San Luis, Argentina;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    caffeine monitoring; Rhodamine B; nylon membranes; multi-walled carbon nanotubes; solid-surface fluorescence;

    机译:咖啡因监测;罗丹明B;尼龙膜多壁碳纳米管;固体表面荧光;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号