首页> 外文期刊>Fire Technology >Examination of the Extinguishment Performance of a Water Mist System Using Continuous and Cycling Discharges
【24h】

Examination of the Extinguishment Performance of a Water Mist System Using Continuous and Cycling Discharges

机译:使用连续放电和循环放电检查水雾系统的灭火性能

获取原文
获取原文并翻译 | 示例
       

摘要

We conducted a series of full-scale fire tests of a twin-fluid water mist system in an empty enclosure and in a simulated machinery space. During the tests, two water mist discharge modes, continuous and cycling, were used. We investigated the extinguishment perfor- mance of the water mist system using these two discharge modes under various fire sce- narios, including different fire sizes, types, and locations, and different ventilation condi- tions.
机译:我们在空旷的机壳和模拟的机器空间中对双流体水雾系统进行了一系列的全面防火测试。在测试过程中,使用了连续和循环两种水雾排放模式。我们在不同的火灾情况下,包括不同的火灾大小,类型和位置,以及不同的通风条件下,使用这两种排放模式研究了水雾系统的灭火性能。