摘要

This paper reports an experimental research into the effect of fire exposure time on the post-fire behaviour of reinforced concrete columns. Nine full-size reinforced concrete columns (45 × 30 × 300 cm) with two longitudinal reinforcement ratios (1.4% and 2.3%) were unexposed and exposed to the ISO 834 standard fire for 2 and 4 h with a constant preload. One month after cooling, the specimens were tested in axial load combined with uniaxial or biaxial bending. The test results show that the residual load-bearing capacity decreases with increase in fire exposure time. This deterioration in strength following an increase in fire exposure time can be slowed down by the strength recovery of hot rolled reinforcing bars after cooling. In addition, the reduction in residual stiffness is higher than that in ultimate load; consequently, much attention should be given to the deformation and stress redistribution of the reinforced concrete building subject to earthquakes after a fire.
机译:本文报道了实验研究火灾时间对钢筋混凝土柱火灾后行为的影响。九个具有两个纵向钢筋比率(1.4%和2.3%)的全尺寸钢筋混凝土柱(45×30×300 cm)未暴露,并以恒定的预紧力暴露于ISO 834标准火中2和4 h。冷却一个月后,在轴向载荷下结合单轴或双轴弯曲对样品进行测试。试验结果表明,残余承载能力随着着火时间的增加而降低。可以通过冷却后热轧钢筋的强度恢复来降低因暴露时间增加而导致的强度下降。另外,残余刚度的降低要比极限载荷的降低高。因此,火灾后地震引起的钢筋混凝土建筑的变形和应力重新分布应引起高度重视。