首页> 外文期刊>Fire Safety Journal >Fire resistance performance of unprotected wood-wood-wood and wood-steel-wood connections: A literature review and new data correlations
【24h】

Fire resistance performance of unprotected wood-wood-wood and wood-steel-wood connections: A literature review and new data correlations

机译:未保护的木-木-木和木-钢-木连接的耐火性能:文献综述和新数据相关

获取原文
获取原文并翻译 | 示例
       

摘要

This paper reviews fire resistance tests of double shear timber connections, including wood-wood-wood connections with nails, bolts and dowels and wood-steel-wood connections with bolts and dowels. Test data are used to assess the effects of the load ratio and the member geometry on the fire resistance of timber connections. New relationships are proposed and analysis results show good agreement with the test results. Design rules presented in Eurocode 5 are also discussed and compared with the proposed calculation method.
机译:本文回顾了双剪切木材连接的耐火性测试,包括带钉子,螺栓和销钉的木木木连接以及带螺栓和销钉的木钢木连接。测试数据用于评估负载比和构件几何形状对木材连接的耐火性的影响。提出了新的关系,分析结果与测试结果吻合良好。还讨论了Eurocode 5中提出的设计规则,并与提出的计算方法进行了比较。

著录项

  • 来源
    《Fire Safety Journal》 |2010年第8期|p.392-399|共8页
  • 作者单位

    Department of Civil and Environmental Engineering, Carleton University, 1125 Colonel By Drive, Ottawa, Ont. K1S 5B6, Canada,Canada Wood, Room 1507, Kuntai International Mansion, 12B Chaowai Street, Beijing 100020, China;

    Department of Civil and Environmental Engineering, Carleton University, 1125 Colonel By Drive, Ottawa, Ont. K1S 5B6, Canada;

    FPlnnovations, Suite 4100 CTTC, 1125 Colonel By Drive, Ottawa, Ont. K1S 5R1, Canada;

    FPlnnovations, Suite 4100 CTTC, 1125 Colonel By Drive, Ottawa, Ont. K1S 5R1, Canada;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    wood; timber connections; fire resistance; fire resistance tests; correlation;

    机译:木;木材连接;防火性能;耐火测试;相关性;