To ensure people's safety in case of fire in buildings it is fundamental to design and manage an effective egress system. Generally, the design and management of the egress system safety is achieved using either the prescriptive codes or performance based tools (mainly evacuation models). In this paper PASS (Preliminary Assessment of the egress System Safety), a method developed to allow a rapid screening of egress system vulnerability, is presented and applied to a case study. PASS is a set of simple analytical equations that allow assessing at different levels of analysis the egress system performance without simulating the evacuation process. It incorporates factors used to include in the assessment the main interrelationships between people-building-environment and to adapt PASS to different scenarios. The method was preliminary applied to a case study (high school). PASS results were compared with two evacuation models (STEPS and FDS+Evac) and data collected from an announced evacuation drill. A good agreement between PASS analysis, the data collected during the evacuation drill and the evacuation models was obtained.
机译:为了确保建筑物发生火灾时人们的安全,设计和管理有效的出口系统至关重要。通常,使用规范性代码或基于性能的工具(主要是疏散模型)来实现出口系统安全性的设计和管理。在本文中,PASS(出口系统安全性的初步评估)提出了一种可以快速筛查出口系统漏洞的方法,并将其应用于案例研究。 PASS是一组简单的分析方程式,可用于在不同分析级别评估出口系统性能而无需模拟疏散过程。它纳入了一些因素,这些因素被用于评估人与环境之间的主要相互关系,并使PASS适应不同的情况。该方法已初步应用于案例研究(高中)。将PASS结果与两种疏散模型(STEPS和FDS + Evac)进行比较,并从宣布的疏散演练中收集数据。在PASS分析,疏散演习期间收集的数据和疏散模型之间取得了良好的一致性。

著录项

  • 来源
    《Fire Safety Journal》 |2013年第5期|92-102|共11页
  • 作者

    S. Grimaz; E. Tosolini;

  • 作者单位

    Dipartimento di Chimica, Fisica e Ambiente, Universita degli Studi di Udine, Via del Catonificio 108, 33100 Udine, Italy,SPRINT Lab-Safety and Protection Intersectoral Laboratory, Universita degli Studi di Udine, Via del Cotonificio 108, 33100 Udine, Italy;

    SPRINT Lab-Safety and Protection Intersectoral Laboratory, Universita degli Studi di Udine, Via del Cotonificio 108, 33100 Udine, Italy;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Egress system; Check; Vulnerability; Safety; Analysis;

    机译:出口系统;校验;漏洞;安全;分析;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号