首页> 外文期刊>Fire Safety Journal >The performance of near-surface mounted CFRP strengthened RC beam in fire
【24h】

The performance of near-surface mounted CFRP strengthened RC beam in fire

机译:近地表CFRP加固RC梁在火灾中的性能

获取原文
获取原文并翻译 | 示例
           

摘要

Carbon fiber reinforced polymers (CFRP) have been widely used in the retrofitting and strengthening of concrete structures. However, the layouts of CFRP in externally bonded (EB) strengthening system and near surface mounted (NSM) system result in the vulnerability of fire resistance. To explore the fire resistance potential of NSM-CFRP strengthening system, 15 RC beams strengthened with CFRP and 2 reference beams were loaded to failure either under the 150834 standard fire or at ambient temperature. In test, the following factors were considered: the strengthening method (near surface mounted technique/externally bonded technique), adhesive (epoxy and magnesium-oxychloride cement), fire protection materials (thin intumescent fire retardant coating and thick fire retardant coating) and location of fire protection (local patch protection/single-sided protection/U-shaped protection). With appropriate fire protection, the RC beams strengthened with NSM-CFRP resisted the standard fire for more than 3 h at high load level. Besides the effects of the aforementioned factors, the friction stress at the CFRP/matrix interface when CFRP is in globally slipping is found playing a crucial role for the fire resistance of NSM-CFRP strengthening system. The experimental observation sheds some light on how the NSM-CFRP strips can retain the contribution at elevated temperatures and why NSM-CFRP strengthening outperforms EB-CFRP strengthening when exposed to fire.
机译:碳纤维增强聚合物(CFRP)已广泛用于混凝土结构的翻新和加固。但是,CFRP在外部粘结(EB)增强系统和近表面安装(NSM)系统中的布局会导致耐火性。为了探索NSM-CFRP加固系统的耐火潜力,在150834标准火灾或环境温度下,将15根CFRP加固的RC梁和2根参考梁加载至破坏。在测试中,考虑了以下因素:加固方法(近表面安装技术/外部粘结技术),粘合剂(环氧和氯氧化镁水泥),防火材料(膨胀型薄防火涂料和厚防火涂料)和位置防火(局部补丁保护/单面保护/ U形保护)。有了适当的防火措施,用NSM-CFRP加固的RC梁在高载荷水平下可以抵抗标准火灾超过3小时。除了上述因素的影响外,当CFRP整体滑移时,发现CFRP /基体界面处的摩擦应力对于NSM-CFRP增强系统的耐火性也起着至关重要的作用。实验观察揭示了NSM-CFRP条带如何在高温下保持贡献,以及当暴露于火中时,NSM-CFRP增强为何胜过EB-CFRP增强。

著录项

  • 来源
    《Fire Safety Journal》 |2017年第6期|86-94|共9页
  • 作者单位

    Tongji Univ, Res Inst Struct Engn & Disaster Reduct, Shanghai 200092, Peoples R China|Shanghai Key Lab Engn Struct Safety, Shanghai 200032, Peoples R China;

    Tongji Univ, Res Inst Struct Engn & Disaster Reduct, Shanghai 200092, Peoples R China;

    Tongji Univ, Res Inst Struct Engn & Disaster Reduct, Shanghai 200092, Peoples R China;

    Tongji Univ, Res Inst Struct Engn & Disaster Reduct, Shanghai 200092, Peoples R China;

    Tongji Univ, Res Inst Struct Engn & Disaster Reduct, Shanghai 200092, Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Strengthening; CFRP; Near surface mounted; Fire resistance; Slip;