首页> 外文期刊>Fire and materials >Experimental and numerical analysis of fire scenarios involving two mechanically ventilated compartments connected together with a horizontal vent
【24h】

Experimental and numerical analysis of fire scenarios involving two mechanically ventilated compartments connected together with a horizontal vent

机译:涉及两个机械通风隔室和水平通风口的火灾场景的实验和数值分析

获取原文
获取原文并翻译 | 示例
       

摘要

This work deals with an experimental and numerical investigation of a fire scenario involving two rooms mechanically ventilated and connected together with a horizontal vent. The objective is to improve the understanding of the physical phenomena and to assess the capability of computational fluid dynamics (CFD) numerical simulations to predict flow field for such a fire scenario. The study is based on a set of large-scale fire experiments performed in the framework of the OECD PRISME-2 project in the DIVA multi-room facility of the Institut de Radioprotection et de Surete Nucleaire (IRSN) and of numerical simulations performed with the ISIS CFD code. The fire scenario consists of two rooms, one above the other, mechanically ventilated and connected to each other with a horizontal vent of 1 m(2). The fire is a heptane pool fire located in the lower room. The analysis focuses on the coupling between the burning rate, the flow at the vent, and the configuration of the mechanical ventilation. Several regimes of combustion are encountered from well-ventilated steady fire to under-ventilated unsteady and oscillatory fire. The results show that the burning rate is controlled by both the mechanical ventilation and the downward flow from the vent. The numerical simulations highlight the specific pattern of the oxygen concentration field induced by the downward flow at the vent.
机译:这项工作涉及对火灾场景的实验和数值研究,其中涉及两个机械通风并通过水平通风口连接在一起的房间。目的是增进对物理现象的理解,并评估计算流体力学(CFD)数值模拟的能力,以预测此类火灾场景的流场。该研究基于在OECD核防护研究所(IRSN)的DIVA多室设施中的OECD PRISME-2项目框架内进行的一系列大规模火灾实验,以及使用该模型进行的数值模拟。 ISIS CFD代码。火灾场景由两个房间组成,一个房间在另一个房间上方,这些房间机械通风并通过1 m(2)的水平通风口相互连接。火是位于较低房间的庚烷池火。分析着重于燃烧速率,通风口处的流量和机械通风的配置之间的耦合。从通风良好的稳定火到通风不良的不稳定和振荡火,都会遇到几种燃烧情况。结果表明,燃烧速率受机械通风和来自通风口的向下气流的控制。数值模拟突出显示了由排气口向下流动引起的氧气浓度场的特定模式。

著录项

  • 来源
    《Fire and materials》 |2019年第5期|514-529|共16页
  • 作者

    Pretrel Hugues; Vaux Samuel;

  • 作者单位

    IRSN, PSN RES, SA2I, Cadarache, St Paul Lez Dur, France;

    IRSN, PSN RES, SA2I, Cadarache, St Paul Lez Dur, France;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    compartment; fire; horizontal opening; under-ventilation; vent;

    机译:隔间;火;水平开口;通风底路;发泄;
  • 入库时间 2022-08-18 04:29:22