Biocompatibility and Long-Term Toxicity of InnoPol~(R) Implant, a Biodegradable Polymer Scaffold

机译:生物可降解聚合物支架InnoPol〜(R)植入物的生物相容性和长期毒性。

获取原文
获取原文并翻译 | 示例
       

摘要

InnoPol~(R), a poly(D,L-lactic-co-glycolic acid) [PLGA] 65/35 scaffold manufactured by special gas foaming methods in Korea, was subjected to tests to evaluate the degradation and tissue compatibility characteristics and long-term systemic toxicity inmice and rats. C57BL/6 mice and SD rats were implanted subcutaneously with 3-mm- and 1-mm-thick InnoPol~(R) circular discs, 10 mm in diameter, respectively, and sacrificed 8, 12, and 24 weeks after implantation. No test material-related effects were observed in mortality, clinical signs, body weight gain, food and water consumption, ophthalmologic signs, urinalysis, hematology, serum biochemistry parameters and organ weights of all animals implanted with InnoPol~(R). Also, there were no systemic symptoms including metabolic alterations and inflammatory reactions in either mice or rats. In addition, no gross pathological findings, except skin lesions around the implantation sites, were found in the major organs. Although mild inflammation at the site of InnoPol~(R) implantation was confirmed from hematoxylin and eosin or Masson's trichrome staining at 8-12 weeks, the reactions had disappeared at 24 weeks following complete degradation of the scaffold, leaving granulomatous tissues that were similar tosurgical wounds in sham operation controls without implants. These results suggest that InnoPol~(R) possesses good mechanical properties and tissue compatibility and does not cause any systemic toxicity other than transient local inflammatory reactionsat the implantation site, and that it might be useful in applications as a medical device for implantation.
机译:通过韩国特殊的气体发泡方法制造的聚(D,L-乳酸-乙醇酸共聚物)[PLGA] 65/35支架InnoPol®经受了测试,以评估其降解和组织相容性,并长期小鼠和大鼠有长期全身毒性。 C57BL / 6小鼠和SD大鼠分别皮下植入直径分别为10毫米的3毫米和1毫米厚的InnoPol?圆盘,并在植入后8、12和24周处死。在所有植入InnoPol®的动物的死亡率,临床体征,体重增加,食物和水消耗,眼科体征,尿液分析,血液学,血清生化参数和器官重量方面均未观察到与测试材料相关的影响。而且,在小鼠或大鼠中均没有全身性症状,包括代谢改变和炎症反应。此外,除了在植入部位周围的皮肤病变外,在主要器官中均未发现明显的病理学发现。尽管在8-12周时由苏木精和曙红或Masson三色染色证实了InnoPol®植入部位的轻度炎症,但在支架完全降解后24周反应消失了,留下了类似于外科手术的肉芽肿组织假手术中的伤口无需植入即可控制。这些结果表明,InnoPol具有良好的机械性能和组织相容性,除了在植入部位的瞬时局部炎症反应以外,不会引起任何全身毒性,并且它可能在用作植入的医疗装置中有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号