首页> 外文期刊>European Radiology >Which Iodine concentration in chest CT? – A prospective study in 300 patients
【24h】

Which Iodine concentration in chest CT? – A prospective study in 300 patients

机译:胸部CT中的碘浓度是多少? –对300名患者的前瞻性研究

获取原文
获取原文并翻译 | 示例
           

摘要

In computed tomography(CT) several contrast media with different iodine concentrations are available. The aim of this study is to prospectively compare contrast media with iodine concentrations of 300, 370 and 400 mg iodine/ml for chest- CT. 300 consecutive patients were prospectively enrolled, under a waiver of the local ethics committee. The first (second, third) 100 patients, received contrast medium with 300(370, 400)mg iodine/ml. Injection protocols were adapted for an identical iodine delivery rate(1.3 mg/s) and total iodine load(33 g) for all three groups. Standardized MDCT of the chest (16 × 0.75 mm, 120 kVp, 100 mAseff.) was performed. Intravascular attenuation values were measured in the pulmonary trunk and the ascending aorta; subjective image quality was rated on a 3-point-scale. Discomfort during and after injection was evaluated. There were no statistically significant differences in contrast enhancement comparing the three contrast media at the pulmonary trunk(p = 0.3198) and at the ascending aorta(p = 0.0840). Image quality(p = 0.0176) and discomfort during injection(p = 0.7034) were comparable for all groups. General discomfort after injection of contrast media with 300 mg iodine/ml was statistically significant higher compared to 370 mg iodine/ml(p = 0.00019). Given identical iodine delivery rates of 1.3 g/s and iodine loads of 33 g, contrast media with concentrations of 300, 370 and 400 mg iodine/ml do not result in different intravascular enhancement in chest-CT.
机译:在计算机断层扫描(CT)中,可以使用几种碘浓度不同的造影剂。这项研究的目的是对胸部CT的碘浓度分别为300、370和400 mg / ml的造影剂进行前瞻性比较。在当地伦理委员会的豁免下,预期连续入选了300名患者。第一名(第二名,第三名)100例患者接受了碘浓度为300(370,400)mg / ml的造影剂。对于所有三组,注射方案均适用于相同的碘递送速率(1.3 mg / s)和总碘负荷(33 g)。进行标准化的胸部MDCT(16×0.75 mm,120 kVp,100 mAseff。)。在肺干和升主动脉中测量血管内衰减值。主观图像质量以3分制进行评分。评价注射期间和注射后的不适感。对比三种增强剂在肺干(p = 0.3198)和升主动脉(p = 0.0840)时,对比增强没有统计学上的显着差异。所有组的图像质量(p = 0.0176)和注射过程中的不适(p = 0.7034)是可比较的。与370 mg碘/ ml相比,注射300 mg碘/ ml造影剂后的一般不适在统计学上显着更高(p = 0.00019)。给定相同的碘传输速率1.3 g / s和33 g的碘负荷,浓度分别为300、370和400 mg / ml的造影剂不会导致胸部CT的血管内增强不同。

著录项

  • 来源
    《European Radiology》 |2008年第12期|2826-2832|共7页
  • 作者单位

    Department of Diagnostic and Interventional Radiology RWTH Aachen University Hospital Aachen Germany;

    Department of Diagnostic and Interventional Radiology RWTH Aachen University Hospital Aachen Germany;

    Department of Diagnostic and Interventional Radiology RWTH Aachen University Hospital Aachen Germany;

    Department of Cardiology Pulmonology and Angiology RWTH Aachen University Hospital Aachen Germany;

    Institute of Medical Statistics RWTH Aachen University Hospital Aachen Germany;

    Department of Diagnostic and Interventional Radiology RWTH Aachen University Hospital Aachen Germany;

    Bayer Schering Pharma AG Berlin Germany;

    Department of Diagnostic and Interventional Radiology RWTH Aachen University Hospital Aachen Germany;

    Department of Radiology University Hospital Maastricht Maastricht the Netherlands;

    Department of Diagnostic and Interventional Radiology RWTH Aachen University Hospital Aachen Germany;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Chest; Contrast media; Contrast material; Iodine concentration; computed tomography;

    机译:胸部;造影剂;造影剂;碘浓度;计算机断层扫描;