首页> 外文期刊>Europace >Reversing cardiac resynchronization therapy non-responder status in a patient with a surgically placed epicardial left ventricular lead by switching to an active fixation coronary sinus lead
【24h】

Reversing cardiac resynchronization therapy non-responder status in a patient with a surgically placed epicardial left ventricular lead by switching to an active fixation coronary sinus lead

机译:通过改用主动固定冠状窦支架导线,通过外科手术放置的心外膜左心室导线可逆转心脏再同步治疗无反应者的状态

获取原文
获取原文并翻译 | 示例
           

摘要

This report describes the reversal of a cardiac resynchronization therapy non-responder status in a patient with a surgically placed left ventricular lead by the use of a newly available active fixation coronary sinus lead.
机译:该报告描述了通过使用新近可用的主动固定冠状窦导线,通过外科手术放置左心室导线的患者中的心脏再同步治疗无反应者状态的逆转。

著录项

  • 来源
    《Europace》 |2008年第10期|p.1234-1235|共2页
  • 作者单位

    1Medical Department, St Adolfstift, Hamburger Street 41, D-21465 Reinbek, Germany 2Cardiology Department, Albertinen-Krankenhaus, Süntelstrasse 11A, D-22457 Hamburg, Germany;