摘要

We assessed factory-calibrated field-portable X-ray fluorescence (pXRF) data quality for use with minimally-prepared aquatic sediments, including the precision of replicate pXRF measurements, accuracy of factory-calibrated pXRF values as compared to total digestion/ICP-OES concentrations, and comparability of calibrated pXRF values to extractable concentrations. Data quality levels for precision, accuracy, and comparability were not equivalent for element/analyzer combinations. All analyses of elements that were assessed for precision and accuracy on a single analyzer were both precise (10% relative standard deviation) and accurate (r(2) 0.85) for K, Ca, Ti, Mn, Fe, and Zn. Calibrated pXRF values for Al, K, Ca, Ti, Mn, Fe, Cu, Zn, and Pb were within similar to 10% relative difference of total digestion/ICP-OES concentrations. Calibrated pXRF values for Fe, Cu, Zn, As, and Pb were within similar to 20% relative difference of extractable concentrations. Some elements had a higher level of data quality using specific analyzers, but in general, no pXRF analyzer had the highest level of data quality in all categories. Collectively, our data indicate that a wide range of factory-calibrated pXRF units are capable of providing high-quality total concentrations for the analysis of aquatic sediments. (C) 2019 Elsevier Ltd. All rights reserved.
机译:我们评估了工厂校准的现场便携式X射线荧光(pXRF)数据质量,可用于最少准备的水生沉积物,包括重复进行的pXRF测量的精度,与总消解/ ICP-OES相比工厂校准的pXR​​F值的准确性浓度,以及校正后的pXRF值与可提取浓度的可比性。元素/分析仪组合在精度,准确性和可比性方面的数据质量级别不相等。在单个分析仪上对元素的准确性和准确性进行评估的所有元素分析,对于K,Ca,Ti,Mn,Fe和Zn均为精确(相对标准偏差<10%)和精确度(r(2)> 0.85)。 Al,K,Ca,Ti,Mn,Fe,Cu,Zn和Pb的校准pXRF值在总消解/ ICP-OES浓度相对差异的10%之内。 Fe,Cu,Zn,As和Pb的校准pXRF值在可提取浓度相对差异的20%以内。使用特定的分析仪,某些元素的数据质量更高,但是总的来说,没有pXRF分析仪在所有类别中都具有最高的数据质量。总体而言,我们的数据表明,许多工厂校准的pXR​​F装置能够提供高质量的总浓度用于分析水生沉积物。 (C)2019 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Environmental Pollution》 |2019年第6期|45-53|共9页
  • 作者单位

    Dalhousie Univ, Dept Civil & Resource Engn, Ctr Water Resources Studies, 1360 Barrington St, Halifax, NS B3H 4R2, Canada;

    Acadia Univ, Dept Earth & Environm Sci, 12 Univ Ave, Wolfville, NS B4P 2R6, Canada;

    Acadia Univ, Dept Biol, 33 Westwood Ave, Wolfville, NS B4P 2R6, Canada;

    Nova Scotia Dept Energy & Mines, POB 698, Halifax, NS B3J 2T9, Canada;

    Dalhousie Univ, Dept Civil & Resource Engn, Ctr Water Resources Studies, 1360 Barrington St, Halifax, NS B3H 4R2, Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号