首页> 外文期刊>Environmental Monitoring and Assessment >Atmospheric aerosols at a regional background Himalayan site: Mukteshwar, India
【24h】

Atmospheric aerosols at a regional background Himalayan site: Mukteshwar, India

机译:喜马拉雅山脉地区背景的大气气溶胶:印度穆克特什瓦尔

获取原文
获取原文并翻译 | 示例
       

摘要

Continuous aerosol measurements were made at a regional background station (Mukteshwar) located in a rural Himalayan mountain terrain from December 2005 to December 2008 for a period of 3 years. The average concentrations of paniculate matter less than or equal to 10 μm (PM_(10)), paniculate matter less than or equal to 2.5 μm (PM_(2.5)) and black carbon (BC) are 46.0, 26.6 and 0.85 μg/m~3 during the study period. Majority of the PM[0 values lie below 100 μg/m~3 while majority of the PM2.5 values lie below 30 μg/m~3. It is further seen that during the monsoon months, especially July and August, the average values are comparatively low. It is also noted that the PM_(2.5)/PM_(10) ratios between 0.50 and 0.75 have the maximum frequency distribution in the data set. Furthermore, the monthly mean ratio of BC to PM_(2.5) mass lies between 3.0 and 7.5 % during the study period. Though the average PM_(10) and PM_(2.5) concentrations during the study period are less than the respective Indian ambient air quality standards, however, they are still above the WHO guidelines and would have adverse health impacts. This shows that even in rural/background regions that are far away from major pollution sources or urban areas, the aerosol concentrations are significant and require long-term monitoring, source quantification and aerosol model simulations.
机译:从2005年12月至2008年12月,在喜马拉雅山区乡村地带的区域背景站(穆克特斯瓦尔)连续进行了3年的气溶胶测量。小于或等于10μm的颗粒物(PM_(10)),小于或等于2.5μm的颗粒物(PM_(2.5))和黑碳(BC)的平均浓度为46.0、26.6和0.85μg/ m在研究期间〜3。大部分PM [0值低于100μg/ m〜3,而大多数PM2.5值低于30μg/ m〜3。进一步可以看出,在季风月份,特别是7月和8月,平均值相对较低。还应注意,在0.50和0.75之间的PM_(2.5)/ PM_(10)比率在数据集中具有最大频率分布。此外,在研究期间,BC与PM_(2.5)质量的月平均比率在3.0%至7.5%之间。尽管研究期间的平均PM_(10)和PM_(2.5)浓度低于各自的印度环境空气质量标准,但它们仍高于WHO准则,会对健康产生不利影响。这表明,即使在远离主要污染源或城市地区的农村/背景地区,气溶胶浓度也很高,需要长期监测,源量化和气溶胶模型模拟。

著录项

  • 来源
    《Environmental Monitoring and Assessment》 |2013年第6期|4753-4764|共12页
  • 作者单位

    The Energy and Resources Institute, IHC, Lodi Road, New Delhi 110003, India;

    The Energy and Resources Institute, IHC, Lodi Road, New Delhi 110003, India,Finnish Meteorological Institute, PO Box 503, 00101 Helsinki, Finland ,Department of Physics, University of Helsinki, PO Box 64, 00014 Helsinki, Finland;

    Finnish Meteorological Institute, PO Box 503, 00101 Helsinki, Finland;

    Finnish Meteorological Institute, PO Box 503, 00101 Helsinki, Finland;

    The Energy and Resources Institute, IHC, Lodi Road, New Delhi 110003, India;

    Finnish Meteorological Institute, PO Box 503, 00101 Helsinki, Finland;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Background site; Fine paniculate matter; Black carbon; Long-range transport; PM_(2.5)/PM_(10) ratio;

    机译:后台网站;细颗粒物;黑炭;远程运输;PM_(2.5)/ PM_(10)比率;
  • 入库时间 2022-08-17 13:27:12

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号