Buildings are often composed of materials with a porous structure. Moisture in the masonry has a destructive impact caused by cycles of drying-wetting and freezing-thawing. A new sensor principle for monitoring moisture in the masonry is presented herein. This sensor utilizes changes in the thermal conductivity of porous structures when they are filled with moist air, water, or ice depending on the existing thermodynamic conditions. Herein, the "hot-ball" method is used to measure the thermal conductivity. The moisture sensor is prepared for porous material corresponding to the parent material, whether it is rock, brick, or concrete. This parent sample is taken from a borehole drilled into the wall. Methodology for moisture sensor calibration is also presented. Sensors were placed in the masonry walls of St. Martin's Cathedral tower in the North, South, and West orientations. The sensors were placed in the plaster and bricks at depths up to 60 mm in the wall surface, just below the window sill. The temperature-moisture regime was monitored from August 19th, 2011 to March 30th, 2012. Changes in temperature and moisture were then correlated with meteorological data.
机译:建筑物通常由具有多孔结构的材料组成。砌体中的水分具有干湿循环和冻融循环的破坏性影响。本文介绍了一种用于监控砖石中水分的新传感器原理。当多孔结构充满潮湿的空气,水或冰时,该传感器利用多孔结构的导热系数的变化,具体取决于现有的热力学条件。此处,“热球”法用于测量热导率。湿度传感器适用于与母体材料相对应的多孔材料,无论是岩石,砖块还是混凝土。该母体样品取自钻入墙壁的钻孔。还介绍了湿度传感器校准的方法。传感器放置在北,南和西方向的圣马丁大教堂塔的砌体墙中。将传感器放置在灰泥和砖块中,位于窗台正下方的墙壁表面,最深为60毫米。从2011年8月19日至2012年3月30日监测温度-湿度状态。然后将温度和湿度的变化与气象数据相关联。

著录项

  • 来源
    《Environmental earth sciences》 |2013年第4期|1481-1489|共9页
  • 作者单位

    Institute of Physics SAS, Dubravska cesta 9, 845 11 Bratislava, Slovakia;

    Department of Engineering Geology, Faculty of Natural Sciences, Comenius University, Mlynska dolina, 842 15 Bratislava 4, Slovakia;

    Faculty of Electrical Engineering, Institute of Nuclear Science and Physical Engineering, STU, Ilkovicova 3, 812 19 Bratislava, Slovakia;

    Institute of Physics SAS, Dubravska cesta 9, 845 11 Bratislava, Slovakia;

    Institute of Physics SAS, Dubravska cesta 9, 845 11 Bratislava, Slovakia;

    Department of Engineering Geology, Faculty of Natural Sciences, Comenius University, Mlynska dolina, 842 15 Bratislava 4, Slovakia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Monitoring; Temperature-moisture regime; Moisture sensor; St. Martin's Cathedral in Bratislava;

    机译:监控;温湿状态;湿度传感器布拉迪斯拉发圣马丁大教堂;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号