摘要

The equilibrium factor F and unattached fraction f_p value, which are important in estimating lung dose, are usually obtained separately. Since both parameters are subject to change according to environmental conditions, it is preferable to measure them simultaneously and continuously. An apparatus which can measure unattached and attached fractions of radon progeny simultaneously with radon gas was developed. When air is introduced into this apparatus, unattached fractions are collected on a metal wire screen, and their activities are detected by a silicon semiconductor detector. Remaining unattached fractions, and attached fractions, are collected on a glass fiber filter. The ~(218)Po concentration and equilibrium equivalent radon concentration(EEC_(Rn)) of the unattached and attached fractions are determined by the build-up method. Radon gas flows into a cylindrical vessel (decay chamber) through a drying column filled with CaCl_2. Radon progeny formed in the vessel is collected by an electric field on a detectable surface of a silicon semiconductor detector. Radon concentration is estimated from the net count of collected ~(218)Po. The apparatus provides data every 30 min. Minimum detectable concentration (with a standard deviation of 50%) is 3 Bq m~(-3) for radon concentration, and below 1 Bq m~(-3) for both ~(218)Po concentration and EEC_(Rn). The apparatus was tested in the laboratory and used in an actual dwelling. In the laboratory measurement, an air circulating system was operated. An increase in f_p and decrease in the equilibrium factor were observed. In the dwelling, the measurement was continuously performed over a 24 h period. Results show that both the equilibrium factor and the unattached fraction obey a lognormal distribution.
机译:通常在评估肺部剂量时很重要的平衡因子F和未连接分数f_p值通常是单独获得的。由于这两个参数都会根据环境条件而变化,因此最好同时进行连续测量。开发了一种可以同时测量ra子气的未附着部分和附着部分的仪器。当将空气引入该设备时,未附着的馏分会收集在金属丝网上,并由硅半导体检测器检测其活动。在玻璃纤维过滤器上收集剩余的未结合的级分和已结合的级分。通过堆积法确定未连接和连接部分的〜(218)Po浓度和平衡当量ra浓度(EEC_(Rn))。 gas气通过充满CaCl_2的干燥塔流入圆柱形容器(腐烂室)。容器中形成的子后代通过电场被收集在硅半导体检测器的可检测表面上。从收集的〜(218)Po的净计数估算浓度。该设备每30分钟提供一次数据。 ra的最低可检测浓度(标准偏差为50%)为3 Bq m〜(-3),而〜(218)Po浓度和EEC_(Rn)均低于1 Bq m〜(-3)。该设备已在实验室进行了测试,并用于实际住宅。在实验室测量中,使用了空气循环系统。观察到f_p的增加和平衡因子的减少。在住宅中,在24小时内连续进行测量。结果表明,平衡因子和未连接分数均服从对数正态分布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号