首页> 外文期刊>Environment international >Asbestos exposure among Seoul metropolitan subway workers during renovation of subway air-conditioning systems
【24h】

Asbestos exposure among Seoul metropolitan subway workers during renovation of subway air-conditioning systems

机译:地铁空调系统改造期间首尔都市地铁工人中的石棉暴露

获取原文
获取原文并翻译 | 示例
       

摘要

Air quality in underground spaces has seldom been evaluated in Korea. Accordingly, the current study recently evaluated asbestos exposure among Seoul metropolitan subway workers during the renovation of the subway's air-conditioning system. To identify possible routes of asbestos exposure, suspected sources, including gaskets, ceiling boards, ceiling materials, and dust settled inside ducts, were all sampled. Personal air samples were also taken to evaluate any asbestos exposure during the renovation. The asbestos fibers found in the samples were analyzed using a transmission electron microscope (TEM) equipped with an energy dispersive X-ray analyzer (EDX). Twelve out of eighteen bulk samples contained asbestos, the majority of which was chrysotile fibers. Asbestos was detected in 9 out of 72 personal air samples and the level ranged from 0.003 to 0.02 fibers/cm~3. While asbestos levels were below Korean occupational limit of 2 fibers/cm~3, they were still detectable and therefore further monitoring would be appropriate.
机译:韩国很少对地下空间的空气质量进行评估。因此,当前的研究最近评估了首尔市地铁工作人员在翻新空调系统时的石棉暴露情况。为了确定石棉暴露的可能途径,对所有可疑来源进行了采样,包括垫片,天花板,天花板材料和沉积在管道内的灰尘。还采集了个人空气样本,以评估装修期间的石棉暴露情况。使用配备有能量色散X射线分析仪(EDX)的透射电子显微镜(TEM)分析样品中发现的石棉纤维。在十八个散装样品中,十二个包含石棉,其中大部分是温石棉纤维。在72个个人空气样本中,有9个检测到石棉,含量范围为0.003至0.02纤维/ cm〜3。尽管石棉含量低于韩国的2纤维/ cm〜3的职业极限,但仍可检测到,因此应进行进一步监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号