首页> 外文期刊>Engineering Structures >Experimental investigations on the influence of size on the performance of RC T-beams retrofitted in shear with CFRP fabrics
【24h】

Experimental investigations on the influence of size on the performance of RC T-beams retrofitted in shear with CFRP fabrics

机译:尺寸对CFRP织物剪力改造的RC T梁性能影响的实验研究

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

More than 85% of the available test data, related to the shear strengthening of reinforced concrete (RC) with externally bonded fiber-reinforced polymer (FRP) composites, have been obtained on beams with effective depths less than 450 mm. Whether or not the beam size influences the shear resistance of RC members retrofitted in shear with FRP, in particular the resistance contributed by the FRP, is a timely question of great interest. This is because the models forming the basis of current guidelines for calculating the contribution of FRP to shear resistance are based on experimental test data. To investigate this question, beams of two different sizes were tested. In total, 12 tests on RC T-beams strengthened in shear with carbon fiber-reinforced polymer (CFRP) composites were performed. The beams were geometrically similar, and the size range was 1:2. The test results clearly showed that the beam size influences the shear resistance contributed by both concrete and the CFRP, but not the shear resistance contributed by the transverse steel reinforcement. Therefore, the shear resistance of the beams with no transverse steel, retrofitted in shear with FRP, is influenced by the beam size. In the beams with a relatively high transverse steel ratio, the shear capacity is strongly dominated by the transverse steel contribution. Hence, the beams with transverse steel appear to be less influenced by the beam size. However, further research is needed to explain fully, and ultimately provide a reliable model for the beam size effect on the contribution of FRP to shear resistance.
机译:在有效深度小于450毫米的梁上,已经获得了超过85%的可用测试数据,这些数据与使用外部粘结的纤维增强聚合物(FRP)复合材料的钢筋混凝土(RC)的剪切增强有关。梁的大小是否影响在FRP剪力后改型的RC构件的抗剪力,特别是由FRP贡献的抗力,是一个非常有意义的及时问题。这是因为模型构成了当前指导原则的基础,用于计算FRP对剪切阻力的贡献,是基于实验测试数据的。为了研究这个问题,测试了两种不同尺寸的光束。总共进行了12次关于碳纤维增强聚合物(CFRP)复合材料在剪力作用下加固的RC T梁的测试。光束的几何形状相似,大小范围为1:2。测试结果清楚地表明,梁的尺寸影响混凝土和CFRP共同作用的抗剪强度,但不影响横向钢筋的抗剪强度。因此,无横梁的梁的抗剪力受梁尺寸的影响。在具有较高横向钢比的梁中,抗剪能力主要由横向钢贡献所决定。因此,横梁的梁受梁尺寸的影响似乎较小。但是,需要进行进一步的研究以充分说明,并最终为梁尺寸对FRP对抗剪强度的影响提供可靠的模型。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号