Assessing the performance of CFRP strengthening on masonry walls using experimental modal analysis

机译:使用实验模态分析评估CFRP加强砌体墙体的性能

获取原文
获取原文并翻译 | 示例

摘要

Strengthening masonry structures using FRP laminates has been widely studied from a resistance point of view. However, there is a need of a non-destructive technique to validate strengthening interventions. In this paper, experimental modal analysis is proposed as a technique to assess practitioners' works. Fifteen brick masonry walls were built and strengthened with five different patterns of carbon-FRP laminates. Experimental modal analysis was performed before and after strengthening interventions. Different vibration modes were compared to select the more sensitive one depending on the strengthening configuration. The change in the vibration frequency was analysed and correlated with cross-section stiffness modification. The obtained results showed changes up to 30% on the vibration frequencies due to strengthening installation. On the overall, the proposed experimental methodology is supported by theoretical analytical calculations with an error under 5% in most of the cases.
机译:使用FRP层压板加强砌体结构已广泛从电阻的角度研究。但是,需要一种非破坏性技术来验证加强干预措施。本文提出了实验模态分析作为评估从业者作品的技术。使用五种不同的碳FRP层压板构建和加强了十五块砖砌体墙。在加强干预之前和之后进行实验模态分析。比较不同的振动模式,以根据强化配置选择更敏感的振动模式。分析振动频率的变化与横截面刚度改性相关。由于加强安装,所获得的结果表明振动频率上的变化高达30%。总的来说,所提出的实验方法由理论分析计算支持,在大多数情况下具有5%以下的错误。