首页> 外文期刊>IEEE Transactions on Electrical Insulation >Experimental study on surface flashover of a coaxial cable under nanosecond impulse voltage
【24h】

Experimental study on surface flashover of a coaxial cable under nanosecond impulse voltage

机译:纳秒脉冲电压下同轴电缆表面闪络的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

The flashover of the polyethylene surface of a coaxial cable is studied under nanosecond impulse voltage. The rise time of the applied voltage is 50 ns. The average impulse flashover voltage per unit length along an insulation length (D) of 5 to 15 cm is measured to be 6.5 to 3.5 kV/cm. The delay time of the flashover is in the range of 500 to 700 ns. The velocity of the propagation of discharge is measured to be (2+or-0.5)*10/sup 7/ cm/s at D=12 cm. In order to compare with the DC values, the DC average flashover voltage for unit length is measured. It is 7.8 to 5.8 kV/cm for D=5 to 15 cm. The voltage time curves of the flashover along the polyethylene and a pressurized spark gap are also given.
机译:研究了纳秒级脉冲电压下同轴电缆聚乙烯表面的闪络。施加电压的上升时间为50 ns。沿着绝缘长度(D)5至15 cm的每单位长度的平均脉冲击穿电压经测量为6.5至3.5 kV / cm。闪络的延迟时间在500到700 ns的范围内。在D = 12cm处测得的放电传播速度为(2+或-0.5)×10 / sup 7 / cm / s。为了与DC值进行比较,测量了单位长度的DC平均闪络电压。 D = 5至15 cm时为7.8至5.8 kV / cm。还给出了沿着聚乙烯的闪络的电压时间曲线和加压的火花隙。