Voltage sags are more and more being considered as a severe power quality problem. However, stochastic prediction tools for voltage sags are rare. The few methods that have been proposed assume a rectangular voltage sag. This assumption is no longer true in many industrial power systems with large induction motor loads. A simple induction motor model has been developed to describe the extra current taken by the motor during the re-acceleration after a short circuit. This model has been incorporated in the method for reliability/power quality analysis of industrial power systems, as described in a previous paper. Simulations are presented to show the influence of the post-fault voltage sag due to motor re-acceleration on the reliability/power quality of the supply. The simulations result in a table with the expected number of interruptions of plant operation for different load sensitivities.
机译:电压骤降​​越来越被认为是严重的电能质量问题。但是,用于电压暂降的随机预测工具很少见。已经提出的几种方法都采用了矩形电压骤降。在许多具有大感应电动机负载的工业电源系统中,此假设不再成立。已经开发出一种简单的感应电动机模型,以描述发生短路后在重新加速期间电动机所消耗的额外电流。如先前的论文中所述,该模型已被并入用于工业电力系统的可靠性/电能质量分析的方法中。进行仿真以显示由于电动机重新加速而引起的故障后电压骤降对电源可靠性/电源质量的影响。通过仿真得出一张表格,其中列出了针对不同负载敏感度的工厂运行中断的预期次数。