摘要

The heat and fluid flow characteristics of rectangular duct having its one broad wall heated and roughened with periodic 'discrete V-down rib' are experimentally investigated. Reynolds number (Re) has been varied from 3000-15000 with relative gap width (g/e) and relative gap position (d/w) range of 0.5-2.0 and 0.20-0.80 respectively. The respective variation in relative roughness pitch (P/e), angle of attack (α) and relative roughness height (e/Dh) have been 4-12,30°-75° and 0.015-0.043. The effect of roughness parameters on Nusselt number (Nu) and friction factor if) has been determined and the results obtained were compared with those of smooth duct. The maximum increase in Nu and/over that of smooth duct was 3.04 and 3.11 folds respectively. The rib parameters corresponding to maximum increase in Nu and/were d/w = 0.65, g/e = 1.0, P/e = 8.0, a = 60° and e/Dh = 0.043. Correlations for the Nu and / in terms of Re and rib parameters have been developed.
机译:实验研究了矩形管道的热和流体流动特性,该矩形管道的一个宽壁被加热并通过周期性的“离散V形向下肋”进行粗糙化处理。雷诺数(Re)在3000-15000之间变化,相对间隙宽度(g / e)和相对间隙位置(d / w)分别为0.5-2.0和0.20-0.80。相对粗糙度节距(P / e),攻角(α)和相对粗糙度高度(e / Dh)的各自变化分别为4-12.30°-75°和0.015-0.043。确定了粗糙度参数对Nusselt数(Nu)和摩擦系数(if)的影响,并将所得结果与光滑导管的结果进行了比较。 Nu的最大增加和/或平滑管的最大增加分别为3.04和3.11倍。对应于Nu的最大增加的肋骨参数和/分别为d / w = 0.65,g / e = 1.0,P / e = 8.0,a = 60°和e / Dh = 0.043。已经开发了关于Nu和// Re和肋骨参数的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号