Experimental study on an open-drive scroll expander integrated into an ORC (Organic Rankine Cycle) system with R245fa as working fluid

机译:以R245fa为工作液的集成到ORC(有机朗肯循环)系统中的开放式涡旋膨胀机的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

The present paper focuses on the experimental characterization of an open-drive scroll expander integrated into an Organic Rankine cycle using R245fa as working fluid. The expander is a commercially available air compressor that was modified to operate in expander mode. The ORC (Organic Rankine Cycle) system is designed for a nominal heat input of 20 kW and a nominal net power output of 1.8 kW. A total of 74 steady-state operating points are measured to evaluate the expander performance over a wide range of conditions. The operating parameters that are varied include the inlet pressure (from 9 to 12 bar), outlet pressure (from 1.5 to 4 bar) and rotational speed (from 2000 to 3500 rpm). The maximum isentropic efficiency and shaft power are, respectively, 75.7% and 2.1 kW. A maximum cycle efficiency of 8.5% is reached for evaporating and condensing temperatures of 97.5 ℃ and 26.6 ℃ respectively. For most of the tests, hot water is produced in the condenser and the system therefore behaves as a CHP (combined heat and power). Depending on the water temperature requirement, a power to heat ratio varying between 1.9% and 11.8% is obtained. Water over 50 ℃ can be produced with a power to heat ratio higher than 8%. The experimental data points are then used to generate a performance map of the expander. This performance map allows for simulation of the use of such an expander in other ORC system.
机译:本文着重于使用R245fa作为工作流体的有机朗肯循环中集成的开放式涡旋膨胀机的实验特性。膨胀器是一种可商购的空气压缩机,其经过修改可在膨胀器模式下运行。 ORC(有机朗肯循环)系统设计用于标称热量输入20 kW和标称净功率输出1.8 kW。总共测量了74个稳态工作点,以评估膨胀机在各种条件下的性能。变化的操作参数包括入口压力(9至12 bar),出口压力(1.5至4 bar)和转速(2000至3500 rpm)。最大等熵效率和轴功率分别为75.7%和2.1 kW。蒸发和冷凝温度分别为97.5℃和26.6℃时,最大循环效率达到8.5%。对于大多数测试,冷凝器中会产生热水,因此系统的行为就像是CHP(热电联产)。根据水温要求,获得的功率与热量的比在1.9%和11.8%之间变化。可以产生超过50℃的水,其电热比高于8%。然后,将实验数据点用于生成扩展器的性能图。该性能图允许在其他ORC系统中模拟使用此类扩展器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号