首页> 外文期刊>Energy >Synthesis of heat exchanger network considering pressure drop and layout of equipment exchanging heat
【24h】

Synthesis of heat exchanger network considering pressure drop and layout of equipment exchanging heat

机译:考虑压降的换热网络综合及换热设备的布置

获取原文
获取原文并翻译 | 示例
           

摘要

The present work is related to development of a MINLP (Mixed integer non linear programming) model for the synthesis of HEN (heat exchanger network) considering pressure drop through connecting pipelines, heat exchangers and the layout of the equipment exchanging heat simultaneously. The pressure drop of shell and tube sides in a heat exchanger is considered in the model. Further, detailed plant layout is considered for accounting pressure drop in pipe line as well as piping cost. The objective function of the MINLP model is the TAC (total annual cost), which considers utility cost, capital investment cost of exchangers, pipe investment cost and pumping cost due to pressure drops in exchanger as well as in pipe length. The developed model is illustrated using a case study. The results show that the TAC of HEN is reduced by 27.4% than that obtained for the topology without considering pressure drop in exchanger. However, placement of exchangers in the layout contributes to 4.5% in TAC. Results found through the present model are compared with that of published models. (C) 2016 Elsevier Ltd. All rights reserved.
机译:目前的工作与开发MINLP(混合整数非线性规划)模型有关,该模型用于综合考虑HEN(换热器网络)通过连接管道,换热器的压降以及同时进行热交换的设备的布局。该模型考虑了换热器中管壳侧的压降。此外,考虑到详细的工厂布局,以解决管道中的压降以及管道成本。 MINLP模型的目标函数是TAC(年度总成本),其中考虑了公用事业成本,交换器的资本投资成本,管道投资成本和由于交换器中的压降以及管道长度引起的泵送成本。使用案例研究说明了开发的模型。结果表明,在不考虑交换器压力降的情况下,HEN的TAC比拓扑获得的TAC减少了27.4%。但是,在布局中放置交换器占TAC的4.5%。将通过本模型发现的结果与已发布模型进行比较。 (C)2016 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号