首页> 外文期刊>Energy >Performance analysis of the mechanical vapor compression desalination system driven by an organic Rankine cycle
【24h】

Performance analysis of the mechanical vapor compression desalination system driven by an organic Rankine cycle

机译:有机朗肯循环驱动的机械蒸汽压缩淡化系统的性能分析

获取原文
获取原文并翻译 | 示例
           

摘要

A desalination system through mechanical vapor compression (MVC), coupling with an organic Rankine cycle (ORC) to drive the steam compressor, is proposed in this paper. Integrated mechanisms of the coupled desalination system are simulated and demonstrated based on the first and second law of thermodynamics, and the corresponding thermal performance is analyzed. Based on the system characteristics at the designed conditions for five types of working fluid, top temperature at the outlet of the boiler and the ambient temperature are designated to illustrate the evocable influence principles. It is observed that the variation trend of the performance both for the ORC and MVC is similar, and the maximum values of the freshwater production and gained output ratio (GOR) are acquired, which are very close for all types of the prescribed working fluid, with in, = 1.09 kgs(-1) and GOR = 3.15 for the case of R245fa. Moreover, it is also obtained that a higher top temperature and a lower ambient temperature are beneficial both for the freshwater production and energy conversion efficiency. (C) 2017 Elsevier Ltd. All rights reserved.
机译:本文提出了一种通过机械蒸汽压缩(MVC)结合有机朗肯循环(ORC)来驱动蒸汽压缩机的脱盐系统。基于热力学第一定律和第二定律对耦合脱盐系统的集成机理进行了仿真和演示,并对相应的热性能进行了分析。基于五种类型工作流体在设计条件下的系统特性,指定了锅炉出口的最高温度和环境温度,以说明可改变的影响原理。可以看出,ORC和MVC的性能变化趋势相似,并且获得了淡水产量和获得的输出比(GOR)的最大值,这对于所有类型的规定工作流体都非常接近,对于R245fa,in = 1.09 kgs(-1),GOR = 3.15。此外,还获得了较高的最高温度和较低的环境温度对于淡水生产和能量转换效率都是有益的。 (C)2017 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Energy》 |2017年第1期|1177-1186|共10页
  • 作者单位

    Nanjing Univ Aeronaut & Astronaut, Coll Energy & Power Engn, 29 Yudao St, Nanjing 210016, Jiangsu, Peoples R China;

    Nanjing Univ Aeronaut & Astronaut, Coll Energy & Power Engn, 29 Yudao St, Nanjing 210016, Jiangsu, Peoples R China;

    Nanjing Univ Aeronaut & Astronaut, Coll Energy & Power Engn, 29 Yudao St, Nanjing 210016, Jiangsu, Peoples R China;

    Nanjing Univ Aeronaut & Astronaut, Coll Energy & Power Engn, 29 Yudao St, Nanjing 210016, Jiangsu, Peoples R China;

    Nanjing Univ Aeronaut & Astronaut, Coll Energy & Power Engn, 29 Yudao St, Nanjing 210016, Jiangsu, Peoples R China;

    Nanjing Univ Aeronaut & Astronaut, Coll Energy & Power Engn, 29 Yudao St, Nanjing 210016, Jiangsu, Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Mechanical vapor compression (MVC); Organic Rankine cycle (ORC); Desalination system; Designed conditions; Gained output ratio (GOR);

    机译:机械蒸气压缩(MVC);有机朗肯循环(ORC);脱盐系统;设计条件;获得的输出比(GOR);