首页> 外文期刊>Energy >A traveling-wave-based protection scheme for the bipolar voltage source converter based high voltage direct current (VSC-HVDC) transmission lines in renewable energy integration
【24h】

A traveling-wave-based protection scheme for the bipolar voltage source converter based high voltage direct current (VSC-HVDC) transmission lines in renewable energy integration

机译:基于双极电压源转换器的高压直流(VSC-HVDC)输电线路的行进波保护方案,可再生能源集成

获取原文
获取原文并翻译 | 示例
           

摘要

The voltage source converter based high voltage direct current (VSC-HVDC) technology is a feasible solution to realize wide-area complementarity and flexible consumption of the renewable clean energy resources but DC line faults are crucial problems. The traditional traveling wave protection for HVDC transmission lines are easily affected by the fault resistance and signal noise. Besides, it cannot detect the double-pole-to-ground fault. To overcome these problems, a single-ended protection scheme based on the phase-mode transformation and wavelet transform modulus maximum (WTMM) theories for DC lines in the VSC-HVDC transmission system is proposed in this paper. The protection scheme includes the protection startup unit, the internal fault identification unit, and the faulty pole detection unit. Extensive simulation tests carried out in PSCAD/EMTDC verify that the protection scheme has high selectivity in the high fault resistance faults, remote faults, and close-by faults with different fault types. And it does not rely too much on data synchronization. Furthermore, sensitivity analysis and comparisons with other methods indicate that the protection is insensitive to signal noise and suitable for different operational modes. And the effectiveness of the protection is independent of the high sampling frequency. Moreover, it can identify the double-pole-to-ground fault correctly.
机译:基于电压源转换器的高压直流(VSC-HVDC)技术是一种可行的解决方案,以实现广域互补性,灵活的可再生清洁能源的互补性,但直流线路故障是至关重要的问题。用于HVDC传输线的传统旅行波保护容易受到故障电阻和信号噪声的影响。此外,它无法检测到双极到地面故障。为了克服这些问题,本文提出了一种基于相位模式变换和小波变换模量的​​单端保护方案(WTMM)VSC-HVDC传输系统中的DC线路的理论。保护方案包括保护启动单元,内部故障识别单元和故障极检测单元。在PSCAD / EMTDC中进行的广泛模拟测试验证了保护方案在高故障电阻故障,远程故障和具有不同故障类型的故障中具有高的选择性。它不太依赖于数据同步。此外,敏感性分析和与其他方法的比较表明保护对信号噪声不敏感,适用于不同的操作模式。保护的有效性与高采样频率无关。此外,它可以正确识别双极到地面故障。

著录项

  • 来源
    《Energy》 |2021年第1期|119312.1-119312.11|共11页
  • 作者单位

    Sichuan University College of Electrical Engineering No.24 South Section 1 Yihuan Road Chengdu 610065 China;

    Sichuan University College of Electrical Engineering No.24 South Section 1 Yihuan Road Chengdu 610065 China;

    Sichuan University College of Electrical Engineering No.24 South Section 1 Yihuan Road Chengdu 610065 China;

    Sichuan University College of Electrical Engineering No.24 South Section 1 Yihuan Road Chengdu 610065 China;

    Sichuan University College of Electrical Engineering No.24 South Section 1 Yihuan Road Chengdu 610065 China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    VSC-HVDC transmission System; DC line; Fault analysis; Traveling wave protection; Wavelet transform modulus maximum;

    机译:VSC-HVDC传输系统;直流线;故障分析;旅行波保护;小波变换模量最大;