Accurate determination of the thermal conductivity of building material is key to calculating its heating/cooling loads and energy consumption. The thermal conductivity of building material is not only related to the pore structure characteristics but also the internal static moisture distribution and moisture transfer characteristics, and the mechanisms of both differ in how they affect the internal heat transfer performance. This paper analyzed the influential quantitative relations between the static moisture distribution and moisture transfer with respect to the thermal conductivity of building materials in different hygrothermal environments. The analysis is based on the additional thermal conductivity calculation method derived from static moisture distribution and moisture transfer proposed by us. The results show that the static moisture distribution has a notable influence on the thermal conductivity under the heating conditions in winter, whereas the influence of moisture transfer is negligible. Nonetheless, the influence of both factors on the thermal conductivity should be considered during air-conditioning in summer. The comprehensive correction rate of the thermal conductivity of building materials in typically hot and humid areas in China are determined, and the influence of the thermal conductivity of moist building materials on the heat transfer coefficient of enclosure structures is analyzed. (C) 2019 Published by Elsevier Ltd.
机译:精确测定建筑材料的导热率是计算其加热/冷却负荷和能量消耗的关键。建筑材料的导热率不仅与孔结构特性有关,而且是内部静态水分分布和湿度转移特性,以及它们如何影响内部传热性能的不同。本文分析了不同湿热环境中建筑材料导热率的静态水分分布与水分转移之间的有影响力的定量关系。该分析基于诸如美国提出的静态水分分布和湿气转移的额外导热性计算方法。结果表明,静态水分分布对冬季加热条件下的导热率有显着影响,而水分转移的影响可忽略不计。尽管如此,在夏季空调期间应考虑两种因素对导热率的影响。确定了中国典型热和潮湿地区的建筑材料导热系数的综合校正率,分析了潮湿建筑材料导热率对外壳结构传热系数的影响。 (c)2019年由elestvier有限公司发布

著录项

  • 来源
    《Energy》 |2019年第1期|103-118|共16页
  • 作者单位

    Xian Univ Architecture & Technol State Key Lab Green Bldg Western China 13 Yanta Rd Xian 710055 Shaanxi Peoples R China|Xian Univ Architecture & Technol Sch Bldg Serv Sci & Engn 13 Yanta Rd Xian 710055 Shaanxi Peoples R China;

    Xian Univ Architecture & Technol Sch Bldg Serv Sci & Engn 13 Yanta Rd Xian 710055 Shaanxi Peoples R China;

    Xian Univ Architecture & Technol State Key Lab Green Bldg Western China 13 Yanta Rd Xian 710055 Shaanxi Peoples R China|Xian Univ Architecture & Technol Sch Bldg Serv Sci & Engn 13 Yanta Rd Xian 710055 Shaanxi Peoples R China;

    Xian Univ Architecture & Technol State Key Lab Green Bldg Western China 13 Yanta Rd Xian 710055 Shaanxi Peoples R China|Xian Univ Architecture & Technol Sch Bldg Serv Sci & Engn 13 Yanta Rd Xian 710055 Shaanxi Peoples R China;

    Xian Univ Architecture & Technol Sch Bldg Serv Sci & Engn 13 Yanta Rd Xian 710055 Shaanxi Peoples R China;

    Xian Univ Architecture & Technol State Key Lab Green Bldg Western China 13 Yanta Rd Xian 710055 Shaanxi Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Energy saving; Moist porous building materials; Thermal conductivity; Correction coefficient;

    机译:节能;潮湿的多孔建筑材料;导热系数;校正系数;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号