The use of a low pressure economizer (LPE) is an effective way to recover waste heat from the exhaust flue gas in thermal power plants. In this paper, an improved bypass staged economizer scheme is presented for China's 600-MW ultra-supercritical power units. The simulation models of the bypass staged economizer and traditional LPE were established based on a 600-MW unit. The simulation results showed that when the presented economizer system was adopted, the temperature of the exhaust flue gas was reduced to near the flue gas acid dew point, thereby greatly improving the energy-saving effects. Compared with the traditional LPE system, the improved economizer system can reduce standard coal consumption rate by an additional 1.1 g/kWh. The bypass ratio under different loads could be adjusted to achieve the best energy-saving effect. The optimum bypass ratio was analyzed under different loads. The results showed that the improved economizer system had a better energy-saving effect by actively controlling the exhaust flue gas temperature. (C) 2018 Elsevier Ltd. All rights reserved.
机译:使用低压省煤器(LPE)是从火力发电厂的废气中回收废热的有效方法。本文针对中国600 MW超超临界机组提出了一种改进的旁路分级节能方案。基于600 MW机组建立了旁路分级节能器和传统LPE的仿真模型。仿真结果表明,采用本发明的省煤器系统后,废气的温度降低到烟气酸露点附近,从而大大提高了节能效果。与传统的LPE系统相比,改进的省煤器系统可将标准煤耗率降低1.1 g / kWh。可以调节不同负载下的旁路比,以达到最佳的节能效果。分析了不同负载下的最佳旁路比。结果表明,改进的省煤器系统通过主动控制排烟温度具有较好的节能效果。 (C)2018 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号