首页> 外文期刊>Journal of the Institute of Energy >Secondary effects in sampling ammonia during measurements in a circulating fluidised-bed combustor
【24h】

Secondary effects in sampling ammonia during measurements in a circulating fluidised-bed combustor

机译:在循环流化床燃烧器中进行测量期间采样氨的次要影响

获取原文
获取原文并翻译 | 示例
           

摘要

A previous paper presented the results of measuring the ammonia (NH_3) concentration in the combustion chamber of a circulating fluidised-bed (CFB) boiler. Two sampling techniques were used: a gas-quenching (GQ) probe where the sample is quenched directly in the probe tip by a circulating trapper solution, and a gas-sampling probe connected to a Fourier-transform infra-red (FTIR) instrument. In this paper, an attempt is made to estimate the influence of potential secondary reactions with HN_3 in the GQ probe tip by means of a plug-flow model.
机译:先前的论文介绍了测量循环流化床(CFB)锅炉燃烧室中氨(NH_3)浓度的结果。使用了两种采样技术:气体淬火(GQ)探针,其中样品通过循环捕集器溶液在探针尖端直接淬灭,以及气体采样探针,与傅里叶变换红外(FTIR)仪器相连。本文尝试通过推流模型估算GQ探针尖端中HN_3潜在的二次反应的影响。