首页> 外文期刊>Energy for sustainable development >Performance analysis of the first photovoltaic grid-connected system in Algeria
【24h】

Performance analysis of the first photovoltaic grid-connected system in Algeria

机译:阿尔及利亚第一光伏网格连接系统的性能分析

获取原文
获取原文并翻译 | 示例
           

摘要

This paper presents an experimental performance analysis based on results attained from monitoring a 9.5 kWp photovoltaic grid-connected for 3 years; from 2016 to 2018. This system is composed of three 3.2 kWp sub-systems installed on the flat roof of the Renewable Energy Development Institute (CDER) in Algeria. This plant covers electricity needs required by the lab and feeds the excess into the low voltage supply grid. This study as-sesses the monthly average and annual performance normalized parameters of the PV system by analyzing and evaluating reference yield, array yield, final yield, system losses, array losses, PV module efficiency, system effi-ciency, inverter efficiency, and performance ratio of the whole system as well as the three sub-systems by follow-ing the IEC 61724 guideline. Results show that the annual average, reference yield, array yield, and final yield, are 4.67, 3.50, 3.37 h/day respectively. While the array and system losses are 1.16 and 0.13 kWh/kWp/day respec-tively. Moreover, the PV module efficiency, system efficiency, inverter efficiency are 8.62%, 8.29%, and 96% respec-tively. These results show that the system is below acceptable performance ratio rates and thus an inspection of the system must be conducted in order to diagnose the reasons behind the system's low productivity. Our study has found that the main attributes contributing to decreased PV outputs are near shading and type of used in-verter (i.e.: Transformerless Inverter). However, the system's performance is still considered satisfactory given it has been functioning for more than 14 years while achieving a performance ratio equivalent to 70%, concluding that the PV grid-connected investment is very promising in this site. (C) 2020 International Energy Initiative. Published by Elsevier Inc. All rights reserved.
机译:本文提出了一种基于监测3.5 kWp光伏网格3年的结果的实验​​性能分析;从2016年到2018年。该系统由安装在阿尔及利亚可再生能源开发局(CDED)的平顶屋顶上安装的三个3.2 kWp子系统组成。该植物涵盖了实验室所需的电力需求,并将过量送入低电压供应网格。本研究通过分析和评估参考产量,阵列产量,最终产量,系统损失,阵列损耗,PV模块效率,系统效率,逆变器效率,逆变器效率,逆变器效率,逆变器效率,逆变器效率,逆变器效率,逆变器效率和性能通过后续IEC 61724指南,整个系统的比例以及三个子系统。结果表明,年平均值,参考产量,阵列产量和最终产量分别为4.67,3.50,3.37 h /天。虽然阵列和系统损失为1.16和0.13千瓦时/ kWp /天/天。此外,光伏模块效率,系统效率,逆变器效率为8.62%,8.29%和96%的重新计。这些结果表明,该系统低于可接受的性能比率速率,因此必须进行对系统的检查,以便诊断系统低生产率背后的原因。我们的研究发现,为降低光伏输出的主要属性是靠近校验中使用的遮蔽和类型(即:无变压器逆变器)。然而,系统的性能仍然被认为是令人满意的,因为它已经运作了超过14年,同时实现了相当于70%的绩效比率,得出结论,即PV网格连接的投资在本网站中非常有前途。 (c)2020国际能源倡议。由elsevier Inc.出版的所有权利保留。

著录项

  • 来源
    《Energy for sustainable development》 |2020年第8期|1-11|共11页
  • 作者单位

    CDER Ctr Dev Energies Renouvelables BP 62 Route Observ Bouzareah 16340 Alger Algeria|Ecole Natl Polytech Lab Dispositifs Commun & Convers Photovolta 10 Ave Pasteur BP 182 El Harrach Alger Algeria;

    CDER Ctr Dev Energies Renouvelables BP 62 Route Observ Bouzareah 16340 Alger Algeria;

    Univ Illinois Dept Urban & Reg Planning Urbana IL USA;

    CDER Ctr Dev Energies Renouvelables BP 62 Route Observ Bouzareah 16340 Alger Algeria;

    CDER Ctr Dev Energies Renouvelables BP 62 Route Observ Bouzareah 16340 Alger Algeria;

    CDER Ctr Dev Energies Renouvelables BP 62 Route Observ Bouzareah 16340 Alger Algeria;

    CDER Ctr Dev Energies Renouvelables BP 62 Route Observ Bouzareah 16340 Alger Algeria;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Performance evaluation; PV Grid-connected; Performance ratio; Algeria;