Combustion of Coal Chars in O_2/CO_2 and O_2/N_2 Mixtures: A Comparative Study with Non-isothermal Thermogravimetric Analyzer (TGA) Tests

机译:O_2 / CO_2和O_2 / N_2混合物中煤焦的燃烧:与非等温热重分析仪(TGA)测试的比较研究

获取原文
获取原文并翻译 | 示例
           

摘要

Two chars prepared from parent coals of a high-volatile bituminous coal and an anthracite coal were subjected to non-isothermal combustion tests in a thermogravimetric analyzer (TGA). The chars were burned in mixtures of O_2/CO_2 and O_2/N_2 with O_2 concentrations of 3, 6, 10, 21, and 30%. A range of non-isothermal combustion tests of each char were conducted with linear heating rates of 2.5, 5,7.5,10, and 12.5 K/min. Detailed comparisons of measured char combustion rates show that replacing the inert nitrogen gas in the oxidizer with CO_2 has very little influence on the measured combustion rates of coal chars at any char conversion level under the conditions of the experiments. Four different model-free isoconversion methods using the experimental data were applied to determine the activation energies of the combustion of chars in O_2/CO_2 mixtures. The results show that the activation energy of each char, determined by any of the four methods, decreases with the increase of the char conversion level. The effect of diffusion, which becomes more pronounced at higher char conversion levels, is believed to be the main reason for the above observation. At a low char conversion level (e.g., 20%), when the effect of diffusion can be neglected, the activation energy of each char determined by the most accurate method under the conditions of this study was found to be in good agreement with literature data: for the anthracite char, it was 138.03 kJ/mol, and for the bituminous coal char, it was 127.83 kJ/mol. The measured combustion rate of each char was found to be approximately first-order to the concentration of O_2 in the O_2/CO_2 mixtures.
机译:由高挥发性烟煤和无烟煤的母煤制备的两种焦炭在热重分析仪(TGA)中进行了非等温燃烧测试。在O_2浓度为3%,6%,10%,21%和30%的O_2 / CO_2和O_2 / N_2的混合物中燃烧炭。每个炭的一系列非等温燃烧测试均以2.5、5、7.5、10和12.5 K / min的线性加热速率进行。对测得的焦炭燃烧速率的详细比较表明,在实验条件下,在任何焦炭转化水平下,用CO_2代替氧化剂中的惰性氮气对测得的煤焦燃烧速率几乎没有影响。应用实验数据,采用四种不同的无模型等转化方法,确定O_2 / CO_2混合气中焦炭燃烧的活化能。结果表明,通过四种方法中的任一种确定的每种炭的活化能随炭转化率的增加而降低。人们认为,扩散的影响在较高的焦炭转化水平下更加明显,这是上述观察的主要原因。在低的焦炭转化率(例如20%)下,当可以忽略扩散的影响时,发现在本研究条件下,通过最准确的方法确定的每种焦炭的活化能与文献数据非常吻合:无烟煤焦为138.03 kJ / mol,烟煤焦为127.83 kJ / mol。发现每个焦炭的测量燃烧速率约为O_2 / CO_2混合物中O_2浓度的一阶。

著录项

  • 来源
    《Energy & fuels》 |2009年第5期|4278-4285|共8页
  • 作者

    Hao Liu;

  • 作者单位

    School of the Built Environment, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号